Страница 1: ...D KDE 9 D KDE 12 D KDE 15 D KDE 18 D KDE 21 D KDE 24 Electric Instantaneous D KDE 27 Water Heater ...

Страница 2: ...sure the long life and reli able operation of this appliance The manufacturer may make minor changes in the appliance if necessary They will not be exposed in the operating instruction so long as the main features of the heater remain the same KOSPEL S A 75 136 KOSZALIN UL OLCHOWA 1 ...

Страница 3: ... up pre heated water e g co operation with a domestic hot water cylinder in a solar system The temperature of the water on the inlet cannot exceed 70 C Description Technical data KDE Bonus water heater 9 12 15 18 21 24 27 Rated power kW 9 12 15 18 21 24 27 Rated voltage 400V 3 Rated current A 3 x 13 0 3 x 17 3 3 x 21 7 3 x 26 0 3 x 30 3 3 x 34 6 3 x 39 0 Supply water pressure MPa 0 1 0 6 Minimal o...

Страница 4: ...ipes to the marked places keeping in mind that the cold water inlet is on the right hand side G1 2 the hot water outlet is on the left hand side G1 2 Figure 2 shows where the heater should be incorporated in the water system 3 Remove the case fig 3 undo the fixing screw 15 take the cover out of bottom catches 16 4 Fix the heater on the fixing hooks after inserting the supply wire through the hole ...

Страница 5: ...r 8 case 15 fixing screw 16 catches 4 5 Fig 5 Safety temperature limiter WT3 a to switch it on b limiter on a b 3 Fig 4 View 8 case 15 fixing screw 16 catches 17 inlet fittings cold water 18 outlet fittings hot water 21 knob 22 coupling fitting ...

Страница 6: ...flow temperature setting set with the use of a knob on the front case and the temperature of water in the mains There are two indicators on the case green power supply on red heating on Other modes are shown through a combination of flickerings of the red and green indicators Number of impulses red indicator the green indicator flickering with constant frequency description 1 the water flow is too...

Страница 7: ...tee In order to clean the filter follow the steps fig 12 1 Shut off power and cold water supplies 2 Remove the case 8 fig 4 undo the fixing screw 15 take the case off 3 Undo the inlet fitting 17 on the cold water side left 4 Take the filter 14 off the inlet fitting 5 Remove impurities from the filter 14 6 Fix the filter 14 with gasket 20 and do up the fittings 7 Open the cut off valve on a cold wa...

Страница 8: ...ire to NA entry on the EKCO boiler When Bonus starts heating the heat ing of the boiler shuts down NA MASTER APPLIANCE entry very rarely used as it does not allow to take a hot water shower if you connect another high power appli ance to this entry the heating of your Bonus heater is blocked when the MASTER APPLIANCE starts to work Fig 8 Inner construction 1 heating box 2 flow sensor 3 WT3 safety ...

Страница 9: ...the above reasons you need to contact an authorised service to have it repaired there is a failure of power supplies the heating is weak or it does not heat at all the plug is not properly connected to the socket lack of 3 phases there is a failure of power supplies the indicators on the case are off Cut off power supplies before taking the case off If the following signals of faulty work are noti...

Страница 10: ...iance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowl edge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance ...