Page 4
3B-390953NI – 01/17
BONNET GRANDE CUISINE
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
•
Only use H07 RN-F type supply cable sized to suit the load of the unit as defined in the table below. (see chapter 1 « technical
characteristics » which give the electrical rating).
Provide an approved omnipolar isolation device, (with at least 3 mm clearance between the contacts).
Intensity (A)
Cable section (mm²)
Intensity (A)
Cable section (mm²)
0.1 to 16
2.5
40 to 63
10
16 to 25
4
63 to 96
16
25 to 40
6
96 to 127
25
7.2
WATER CONNECTION
- To ensure that the mains water supply is protected and to comply with current regulations a backflow prevention devise conforming to CAa
standard (Ovens fitted with automatic wash function including an integral detergent pump) as per norms : EN14367 or EA (all other units) to
norms EN13959 and in compliance with local regulations (WRAS, SVGW, DVGW).
Pipework and anti-pollution protection is not fitted because the distance between the water supply and the unit are variable. Installation,
connection and commissioning should be undertaken by specialist concessionaires or authorised personnel.
- Nature: 168 µm filter integral with the oven
- Conductivity: Min 20 µS/cm2
- Water quality: Maximum concentration of Chloride Cl
-
: 100 mg/l and Chlorine Cl
2
: 0.2mg/l
- Provide a local stop cock.
Attention (UK
specification
): Fit an approved double check valve to comply with local water regulations.
Watter supply
7.3
DRAIN CONNECTION
The water discharged could be condensate and at very high temperature (98°C).
Only use materials suitable for these temperatures.
The oven is equipped with a trap which connects the appliance directly to the
external drainage system to comply with pollution control standards.
It is vital that there is a trap between the unit and the drainage system to prevent
back odours
7.4
CONNECTION OF CLEANING PRODUCTS
The oven has an automatic cleaning system to wash the cooking cavity.
Never use descaling product in the automatic cleaning system. This could seriously damage the ovens
hydraulic circuits.
Except for the UK market: No detergent product is recommended or supplied. Any detergent used with this appliance must have been verified to
represent no greater risk than Fluid Category 3. If the detergent used represents a Fluid Category risk greater than Fluid Category 3 alternative
backflow protection to the double check valve supplied with the appliance will be required immediately upstream of the appliance. The backflow
protection used must be appropriate to the risk posed by the detergent.
Attention: The nature and length of the detergent hose should not be altered in any way
The detergent inlet hose is identified by a label and a coloured plug to ensure it is placed in the correct container:
Note: Refer to the “Installation: Recommendations section” chapter when handling or using these chemicals, if in
any doubt refer to the products safety sheet
35mm
∅
minimum
internal