14.4.10.2
Sequence Example
To start the Electronic Gear: Slave mode, the correct sequence has to be sent from
the PLC.
1 Control word =
0x0000
Disable voltage
1 Status word =
0x0050 Switch On Disabled
2 Modes of Operation = -3
(Electronic Gear: Slave mode)
3 Control word =
0x0006
Shutdown
Status word =
0x0031 Ready to switch on
4 Control word =
0x0007
Switch On
Status word =
0x0033 Switched On
5 Control word =
0x000F
Enable Operation, Reference speed “0”.
Status word =
0xnn37 Operation enabled
6a Control word =
0x001F
Start Electronic Gear without Direct Syn-
chronisation
Status word =
0xn327 Operation enabled, Slave not coupled (yet),
Phasing not finished.
Status word =
0xn337 Operation enabled, Slave not coupled (yet),
Phasing finished.
Status word =
0xn727 Operation enabled, Slave coupled, Phasing
not (yet) finished.
Status word =
0xn737 Operation enabled, Slave coupled, Phasing
finished.
6b Control word =
0x005F
Start Electronic Gear with Direct Synchroni-
sation
Status word =
See 6a See 6a
7a Control word =
0x021F
Start Electronic Gear without Direct Syn-
chronisation and Phasing Profile 1
Status word =
See 6a See 6a
7b Control word =
0x121F
Start Electronic Gear without Direct Syn-
chronisation and Phasing Profile 2
Status word =
See 6a See 6a
7c Control word =
0x221F
Start Electronic Gear without Direct Syn-
chronisation and Phasing Profile 3
Status word =
See 6a See 6a
7d Control word =
0x321F
Start Electronic Gear without Direct Syn-
chronisation and Phasing Profile 4
Status word =
See 6a See 6a
8a Control word =
0x025F
Start Electronic Gear with Direct Synchroni-
sation and Phasing Profile 1
Status word =
See 6a See 6a
8b Control word =
0x125F
Start Electronic Gear with Direct Synchroni-
sation and Phasing Profile 2
Status word =
See 6a See 6a
8c Control word =
0x225F
Start Electronic Gear with Direct Synchroni-
sation and Phasing Profile 3
Status word =
See 6a See 6a
8b Control word =
0x325F
Start Electronic Gear with Direct Synchroni-
sation and Phasing Profile 4
Status word =
See 6a
Disable voltage
9 Control word =
0x001F
0x003F
Enable Operation, the Slave drive synchro-
nizes to the Master position.
Status word =
0xnn37
0x1n37
Operation enabled
M/S Position Correction finished.
184
CM-EtherCAT
07/13