14.4.8
Table travel record
The table travel record mode is selected via object
= 0xFF =-1. In table travel record mode the inverter moves the drive autono-
mous to consecutive positions.
The table travel record mode uses predefined sets of positions. Every target position
is defined by one motion block. Several sets of motion blocks may be defined.
For an exact description of table travel record mode options refer to the application
manual “Positioning”.
Related objects:
In table travel mode the "operation mode specific" and “manufacturer specific” bits of
Control word and Status word are used as shown:
Control word
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit
0
Switch on
1
Enable voltage
2
Quick stop (Low active)
3
Enable operation
4
Sequence mode
5
-
6
Resume
7
Fault reset
8
Halt
9
Start motion block
10
-
11
Motion block select 0
12
Motion block select 1
13
Motion block select 2
14
Motion block select 3
15
Motion block select 4
07/13
CM-EtherCAT
163