14.4.6
Cyclic Synchronous position mode
The Cyclic Synchronous position mode is selected via object
= 8. In Cyclic Synchronous position mode the inverter receives a target position
at equidistant time intervals.
Related objects:
Controlword
Statusword
Velocity min max amount
Modes of operation
Modes of operation display
Target Position
Quick stop deceleration
In Operation mode
Cyclic Synchronous position mode only the 4 lowest bity are used
for control.
Control word
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit
0
Switch on
1
Enable voltage
2
Quick stop (Low active)
3
Enable operation
4
-
5
-
6
-
7
Fault reset
8
Halt
9
-
10
-
11
-
12
-
13
-
14
-
15
-