background image

BONDIS bvba 

– Cleydaellaan 16/1  – 2630 Aartselaar – BELGIUM 

Tel .: +32 3 234 29 18 

– Fax: +32 3 233 13 10 – Email: [email protected] 

ISO 9001:2008 n° 22714 

– www.bondis.com 

 

 

 

 

 

 

 

Easylube® 150 Classic – 

Service 

Guide 

Re-usable single-point automatic lubricator  

 
 

Step 1.

  

Preparation:

 

 

► If you purchased empty grease cup, fill the cup with lubricant as below. 

 

 

 

Caution : 

If the cup is being filled for the first time, the red piston must be pressed down to bleed air. Fill the 
empty grease cup until the red piston reaches the top and in a level position.  
 
 

Step 2.

  

Position the press plate: 

 

► Facing the bottom of the body assembly, turn the press late clockwise until it seats. 
 
► Next, rotate the press plate counterclockwise with a ¾ turn. 
 
► Screw the prefilled grease cup into the body assembly securely and make sure the press plate 
touches the red piston in the cup. If done properly, a small amount of grease is supposed to 
discharge when the cup is securely screwed in. 

 

 

Caution : 

Falling to engage the press plate and the red piston will disable the piston movement and result 
in zero grease output after start-up. 
 
 
 

Содержание Easylube 150 Classic

Страница 1: ...l the empty grease cup until the red piston reaches the top and in a level position Step 2 Position the press plate Facing the bottom of the body assembly turn the press late clockwise until it seats Next rotate the press plate counterclockwise with a turn Screw the prefilled grease cup into the body assembly securely and make sure the press plate touches the red piston in the cup If done properly...

Страница 2: ...attery back to restart Step 4 Set change the dispense period time Remove the battery from the body assembly Set the levers on the switch to correspond to the time perod required Table 1 DIP switch setting for dispense period time Dispense period DIP switch ON Time span between cycles Amount cycle Amount day Amount week Amount month Month Hours ml ml ml ml 1 1 2 0 417 5 35 150 2 2 4 2 5 17 5 75 3 1...

Страница 3: ...nsing Caution Every time the DIP switches are reset the battery must be removed for approximately 15 seconds to clear the CPU memory Step 6 Installation preparation Flush the bearing and the pipeline completely with same grease or compatible with that in the prefilled grease cup The flushing process mustbe done slowly stroke by stroke to detect any potential blocking in the pipeline or bearing Whe...

Страница 4: ...psi 5 2 bar or higher Always keep the number of bends and the length of extension line to a minimum Important Always install the lubricator at a rigid and stable position Use copper piping hardware when the bearing temperature exceeds 50 C PU tubing harware can be used at bearing temperature lower than 50 C Installation steps 1 Remove grease nipple from bearing 2 Select the right size of adapter a...

Страница 5: ...he bearing Therefore it is importnt to replace the battery at the end of a dispensing period or anytime the voltage is below 6V Table 3 Lubricator dispense period compared with DIP switch lever positions and battery life Dispense period in months DIP switch ON Battery life in days Dispense period in months DIP switch ON Batery life in days Dispense period in months DIP switch ON Battery life in da...

Страница 6: ...e manufactuer for information Back pressure exceeds 75 psi 5 2 bar USe test apparatus to measure back pressure Lubricator lines not completely filled Fill the bearing and pipeline manually with same or compatible grease Lubrication period incorrectly set up Shorten the lubrication period and observe the changes Lubricator does not dispense Weak battery Verify the output voltage of battery exceeds ...

Отзывы: