MCH_HQ00
5
STATIX R DP
Crucibles: 350, 600 or 1000 cc
This instruction manual is an integral part of the machine supply
and should accompany it whenever it is moved.
The manual must be carefully kept for the duration of the
machine's life and must in all cases be available for at least 10
years, it must therefore be kept in a known location and made
available to all the personnel concerned.
Do not connect the machine or put it into operation until this
manual has been read.
Pict.1
1
Optical reader
8 Water pump socket
2
Crucible lock lever
9 Water inlet pipe connection
3
Main switch
10 Water outlet pipe connection
4
Argon pipe
11 Water pump support
5
Casting area protection grid 12 Crucible tilting lever
6
Circuit breaker
13 Compressed air inlet
7
Power
supply
covering
panel
14 Argon gas inlet
STATIX F DP
is avabile in the following versions:
380V 50-60Hz
Power
15kW
Depth
94 cm
Width
112 cm+ 20 cm for water pump
Height
117 cm + 34 cm of the optical reader
support
Controllable
temperature range:
800
1999°C
STATIX R DP
is an electronic casting machine for alloys used in
jewellery technology field. Its aim is to melt by induction the alloy
placed in a special crucible. Once liquid the alloy can be poured
into the mold tilting the crucible by means of a special lever.
Any use other than the one described above is to be considered
improper and releases the manufacturer from all liability for
damage of any type and nullifies tha warranty rights on the
equipment itself.
The machine must be used by adult and suitably trained
personnel.
Given the weight of the machine, it must only ever be moved
with an appropriate trolley or on its wheels.
Never horizontally tilt the machine when moving or
transporting it. The machine must always rest on its feet.
If the machine needs to be moved after it has been installed,
always firstly empty the water from the tank.
Wear the dark glasses supplied. The light emitted from the
metal being cast could damage your sight.
Always use the relevant grips for removing the crucible.
Make sure that the electrical system has a ground fault
interrupter.
INTRODUCTION
SPECIFICHE TECNICHE
PURPOSE OF THE EQUIPMENT
PRECAUTIONS
TECHNICAL SPECIFICATIONS
1
3
6
7
2
5
12
4
14
13
10
9
11
8