MMR2003_018_00_02A.FM
XI
INTRODUCTION
CASE-IN COMPONENTS
Metallic Gaskets
1. Proper strength Loctite
1. Clean inner housing diameter and outer gasket
diameter.
2. Spray housing and gasket with Loctite Primer N
(P/N 293 800 041).
3. Apply a strip of proper strength Loctite on lead-
ing edge of outer metallic gasket diameter.
NOTE:
Any Loctite product can be used here. A
low strength liquid is recommended as normal
strength and gap are required.
4. Install according to standard procedure.
5. Wipe off surplus.
6. Allow it to cure for 30 minutes.
NOTE:
Normally used on worn-out housings to
prevent leaking or sliding.
It is generally not necessary to remove gasket
compound applied on outer gasket diameter.
A00A3VA