21
temperatures, the compressor will run more fre-
quently and longer.
Ensure enough ventilation at the bottom and rear
side. Never block ventilation openings.
Place all shelves, racks or drawers (depending on
the model) in their original position.
Adjust the temperature not colder than necessary.
Allow warm food to cool before placing it in the
appliance.
Open the unit door only as necessary.
Defrost the unit regularly (model dependent).
The seal of the appliance door must be complete-
ly intact, so that the door closes properly.
Cleaning and Maintenance
WARNING:
Always disconnect the appliance from the power
supply before cleaning and user maintenance.
Do not use steam cleaners for cleaning the appli-
ance; moisture could enter electrical components.
Risk of electric shock! Hot steam could damage
the plastic parts.
The unit must be dry before restarting operation.
CAUTION:
Do not use a wire brush or other sharp, abrasive
items.
Do not use any acidic or abrasive detergents.
Do not damage the refrigerant circuit.
Cleaning the appliance including interior
Clean the appliance interior, the exterior surfaces,
the accessories and the door seal regularly with
warm water and mild detergent; or with a clean,
damp microfiber cloth without cleaning agent.
Remove the appliance content and storage it at a
cool location.
Clean the thaw water discharge channel / opening
carefully e.g. with a pipe cleaner.
After everything was thoroughly dried, you can
restart the operation.
Defrosting
CAUTION:
Never use metal objects (e.g. knifes) to remove ice
from the evaporator. Otherwise it can be damaged.
The appliance has an automatic defrosting system.
During defrosting water drops drains off at the back
of the cooling chamber. The thaw water running
through a channel, is collected in a drip tray located
on the compressor, where it will evaporate. Make
sure the water discharge opening does not get
clogged. A light formation of ice on the interior back
during operation is normal.
Changing the bulb
CAUTION:
Do NOT remove the cover of the interior light.
The LED light may be replaced / repaired in case of
failure / defect only by an authorized specialist.
Troubleshooting
Before you contact an authorized specialist
Problem
Cause / Action
Unit is not
working
properly or
at all
∙ Check the power supply / tem-
perature setting / ambient temper-
ature. ∙ Unblock the ventilation
openings, install the unit freely.
Loading is
too warm
∙ Check the temperature setting /
ambient temperature. ∙ Open the
door only as long as necessary.
Loud noise
during opera-
tion
∙ Check the appliance position.
∙ See the section “Operating
noise”.
Содержание VS 7316.1
Страница 23: ...23...
Страница 24: ...24 C Bomann GmbH www bomann germany de Made in P R C Stand 08 2020...