Bolttech-Mannings TP30K-Z-DP Скачать руководство пользователя страница 1

 

 

BOLTTECH MANNINGS  

TP30K-Z-DP  

OWNERS MANUAL  

10/10

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

 
 
 
 
 
 
 
 

BOLTTECH-MANNINGS Inc. 

501 Mosside Blvd. 

North Versailles, PA 15137  USA 

Phone: 724-872-4873 

www.bolttechmannings.com

  

Содержание TP30K-Z-DP

Страница 1: ...BOLTTECH MANNINGS TP30K Z DP OWNERS MANUAL 10 10 BOLTTECH MANNINGS Inc 501 Mosside Blvd North Versailles PA 15137 USA Phone 724 872 4873 www bolttechmannings com...

Страница 2: ...n area ratio of 440 1 between the pneumatic piston and hydraulic plunger This relates to a maximum hydraulic output pressure that is 440 times greater than the pneumatic drive pressure e g With 50 psi...

Страница 3: ...reservoir close the main air shut off ball valve 7 Adjust the air regulator on top of unit until desired air pressure is achieved as indicated on the air gauge and push in the handle to lock in place...

Страница 4: ...set to desired pressure Attach hoses to Bolttech Mannings Hydraulic Stud Tensioners Rotate and close Oil Return Valve to build hydraulic pressure turn clockwise Turn on the pump and run unit by holdin...

Страница 5: ...USE ONLY ORIGINAL BOLTTECH MANNINGS SPARE PARTS THE AIR DRIVES OF ALL LIQUID PUMPS ARE FACTORY PRE TREATED WITH SILICON FREE GREASE KLUBER LUBE AND REQUIRE NO FURTHER LUBRICATION EXCEPT DURING ROUTINE...

Страница 6: ...ir Shut Off Valve TP30K Z 4 5 Air Hydraulic Pump TP30K Z 3 6 Oil Return Valve TP30K Z 6 7 Pressure Gage TP30K Z 7 8 Dip Stick TP30K Z 8 9 Frame TP30K Z 9 10 Lifting Handle TP30K Z 10 11 Drain Plug TP3...

Страница 7: ...MODEL TP30K Z DP PARTS DIAGRAM 1...

Страница 8: ...e TP30K Z 7 Filler Cap Dip Stick TP30K Z 8 Air Pressure Gage TO30K Z 14 Needle Valve Oil Return Valve TP30K Z 6 Air control valve Pump on off valve TP30K Z 4 Air Pressure Regulator TP30K Z 1 Model TP3...

Страница 9: ......

Страница 10: ...MODEL TP30K Z DP PARTS DIAGRAM 3...

Страница 11: ...d air escapes through the exhaust muffler Cause Pilot valve tappet is not sealing in top cap Remedy Clean and grease tappet check for wear and replace if necessary Symptom Pump will not run and air es...

Страница 12: ...s blocked 6 High pressure seal is worn excessively Remedy I I Check suction line and pipe joints for leaks 1 2 Check seals between air and high pressure sections 2 Shorten line as much as possible 3 I...

Страница 13: ...ent to allow the tensioning tool to engage the stud a minimum of one 1 stud diameter Check that the tensioner is seated squarely on the bridge piece and that the bridge is seated squarely on the work...