background image

S2000-К

41

www.bolid.com

User’s Code
Entered

ECOD      80     D007

A user has presented to a reader of the device with
the network address 7 the authenticator #80 regis-
tered by the network controller

Local User’s
Code Entered

ECOD    405(l) D001

A user has presented to a reader of the device with
the network address #1 the authenticator #405 regis-
tered by the device itself

Device Tamper
Alarm

TA         D001

The enclosure of the device with the network address
1 has been open

Device Tamper
Restored

TR         D001

The enclosure of the device with the network address
1 has been closed

Device
Connected

CONNECT  D018

The network controller has found the device with the
address 18 within the connected RS-485 interface bus

Device
Disconnected

DISCONNECT  D018

Communication between the network controller and
the device with the network number 18 has been lost:
or the device has been replaced

Device Restarted

RESTART   D018

The device with the network address 18 has been re-
started

Power Failure

PWRF  D018

The input voltage of the device with the network ad-
dress 18 is out of the normal range

Access
Granted

AG        41   D001

The device with the network address 41 has made a
decision to grant access via its protected door to  a
user having presented the authenticator #41

Access Denied

AD         41   D001

The authenticator #41 has been read by a reader of
the device with the network address 1, the authentica-
tor being not authorized to gain access to the opera-
tion requested

Illegal Code

ICOD         D001

An unknown authenticator has been presented to a
reader of the device with the network address 1

Door Forced Open

DRF           D001

The door monitored by the device with the network
address 1 has just been open without granting access

Door Held Open

DRO          D001

The door monitored by the device with the network
address 1 has been open for more than a specified
time

Door Closed

DRC          D001

The door monitored by the device with the network
address 1 has just been closed after being held open
or forced open

Local
Programming

PROGR    D001

The device with the network address 1 has entered
the Key Programming Mode

Содержание S2000-K

Страница 1: ...Orion ISS KEYPAD S2000 K User s Manual ...

Страница 2: ...he actuated detector can be located only with the accuracy of the alarm loop Zone A minimal part of a security and safety installation that can be monitored and controlled inde pendently Depending on the context the term zone can imply an alarm loop an addressable detector a hardwire component etc Partition A set of zones that can be user controlled as a whole As a rule zones fall into partitions ...

Страница 3: ...necting the Orion RS 485 Interface Bus 25 Connecting the Power Supply 25 Getting Started 26 Programming 27 Programming the Keypad 28 Programming the Network Address of the S2000 К 29 Programming the S2000 K to Display Events and Indicate Alarms 30 Network Controller Settings 31 How to enroll the S2000 К to the Console Database Using PProg 31 Programming the Console for Receiving Commands from the ...

Страница 4: ...Orion ISS www bolid com 4 ...

Страница 5: ...S2000 К Features and Design 5 www bolid com FEATURES AND DESIGN ...

Страница 6: ... the S2000 K LCD Users can also be authenticated by means of access de vices such as Touch Memory devices DS iButtons or Proximity cards pre registered by the network controller and presented to one of the Orion ISS readers After a user has been authenticated all ac tivities permitted to him are carried out by operating with the S2000 К keypad The S2000 К keypad can be used also as an output devic...

Страница 7: ...ypad being in the Event Display mode its LED indicator 1 indicates the fact of re ceiving a message from the network controller by steady lighting If in addition the mode of indicating alarms is set on the LED indicates raw alarms by blinking The buttons 3 are used to input user commands to switch the keypad LCD into display modes see above to browse event log records and to clear alarm messages T...

Страница 8: ...Orion ISS www bolid com 8 ...

Страница 9: ...event log for storing last 255 received events Ø Light and Sound Alarm Indication Ø Non volatile event log for storing last 16 keypad events Ø Input Voltage 10 2 28 4 VDC Ø Consumed Current 50 mA 12 VDC or 25 mA 24 VDC Ø Operating Temperatures 1 С to 40 С Ø Overall Dimensions 146 105 35 mm Ø Enclosure Material Plastic ...

Страница 10: ...Orion ISS www bolid com 10 ...

Страница 11: ...S2000 К Operating 11 www bolid com OPERATING ...

Страница 12: ...ications between the keypad and the network controller is lost the S2000 К LCD displays the message COMMUNICATIONS LOST and the keypad LED flashes once per second In such a case all user operations with the keypad S2000 K i e typing a password observing mes sages and requesting access become unavailable In the quiescent mode the S2000 К beeper is turned off Pressing the buttons on the keypad is ac...

Страница 13: ...e S2000 К gives an Error signal and displays an access reject message with specifying one of the reasons as follows ILLEGAL CODE The authenticator presented is not registered by the network controller ACCESS DENIED The authenticator presented has no authorities to gain access via the specified door or access is blocked for this one WRONG PARTITION The authenticator presented has no authorities to ...

Страница 14: ...cess rights the number of one of the doors accessible to the user will be represented on the LCD Using buttons t and u select the necessary door number or type it from 1 to 9999 by number buttons and then press ENTER In case of success the positive access message will be displayed on the S2000 K LCD and the beeper will produce the Success signal Otherwise the beeper will produce the Error audible ...

Страница 15: ... control mode before input of the password presenting electronic access device it is necessary to press the ON button inputting the password without pressing the ON button in this case will initiate an access request After the correct password electronic access device is presented status of one of the user accessi ble partitions is represented on the S2000 K display The partitions can be in follow...

Страница 16: ...ess device is correct the keypad displays a status of the first partition accessible to the user see above The example shows partition 1200 being in DISARMED status To review the statuses of all accessible partitions scroll the list using the t and u or type numbers of the required partitions using the relevant S2000 K buttons To arm a partition select it number from the list using the t and u but...

Страница 17: ...e network controller the S2000 K produces the Error beep and displays the ILLEGAL CODE message followed by switching to the Time Display mode After thrice repeated entering of invalid passwords the keypad blocks password inputting for 30 seconds If the password electronic access device is correct the keypad displays the status of the first partition accessible to the user The example shows the 120...

Страница 18: ...layed for 15 seconds For forced exit into the Time Display mode it is necessary to press CLEAR The last 255 received messages are stored in the S2000 К non volatile memory The buttons t and u are intended to browse the message log with scrolling messages in direct chronological order be ing executed by the t button and scrolling in reverse order being executed by the u button To re view the time o...

Страница 19: ...g by the operator and does not change a status of the alarm system when an alarm is unset by the S2000 K operator the actual system zone keeps being in the alarm status as well as resetting alarms in the alarm system does not lead to resetting this alarm for the S2000 K The alarms unlike other messages provided that the alarm indication mode is set for the S2000 K are displayed by the S2000 K up t...

Страница 20: ... Review statuses of available partitions t or u Select the relevant partition from the list of available ones t or u or a door Enter the arming disarming menu ENTER Select the command if available t or u s Confirm the selected command ENTER Reviewing System Messages Review the event log ENTER Browse the event log forward from the Time Display mode t Browse the event log backward from the Time Disp...

Страница 21: ...EVICE RESET TAMPER ALARM The device enclosure has been open TAMPER RESTORED The device enclosure has been closed The keypad provides buffering of events that should be transmitted to the network controller via RS 485 interface in case of communication loss After a minute since an event has occurred but not transmitted the event is assigned to a time in accordance with the internal keypad clock The...

Страница 22: ...Orion ISS www bolid com 22 ...

Страница 23: ...S2000 К Installation 23 www bolid com INSTALLATION ...

Страница 24: ...S2000 K Overall and Mounting Dimensions The S2000 K is to be mounted on walls or other constructions within the premises which are pro tected against atmospheric fallouts mechanical damage and unauthorized access Select the mounting location that is to be approximately 1 5 m above the floor The S2000 K overall and mounting dimensions are shown in Figure 1 4 holes Æ 4 95 105 65 35 146 ...

Страница 25: ...istor 620 W across the А and В terminals of the ХТ1 2 WARNING If the RS 485 interface bus is quite long more than 1000 meters use twisted pair ca bling to connect the devices The resistance value of each RS 485 interface line A or B measured between the network controller and the most distant device MUST NOT exceed 200 W Connecting the Power Supply Connect a direct power supply 10 28 V 100 mА to t...

Страница 26: ...ng communicated with the network controller over the RS 485 interface the keypad LCD shall display the current time Otherwise the keypad LCD shall display NO RS485 LINE the keypad LED flashing once per a second In order the S2000 K to operate as a part of an Orion system it must be assigned to a unique network address see Section Programming the Network Address of the S2000 К of this Manual ...

Страница 27: ...S2000 К Programming 27 www bolid com PROGRAMMING ...

Страница 28: ...000 S2000M S2000L controls the system or Database Administrator Software tools if the system operates under the Orion Software PROGRAMMING THE KEYPAD The S2000 K keypad can be programmed by means of the UProg Configuration Tool To install the UProg download its archive to the PC and unpack it to the relevant directory for exam ple the C Program Files UProg Run the UProg exe file or create its shor...

Страница 29: ...s a text into an MS Word file File Экспорт конфигурации в Microsoft Word The S2000 К stores its settings in its non volatile memory To identify the S2000 K keypad within a group of devices of an Orion system the keypad must be assigned to a unique number within the RS 485 interface line the network address ranged from 1 to 127 see below The factory setting for the network address of each Orion sys...

Страница 30: ... supposed to in dicate system alarms by flashing its LED and issuing various sound signals the Indicate Alarms key pad option must be activated WARNING In order to use the keypad for displaying messages and indicating alarms you MUST AL SO REVISE settings of the network controller see page 31 By default displaying system event messages and indicating alarms are disabled for an S2000 K To activate ...

Страница 31: ...nd ØEnable managing the partitions by means the S2000 K keypad in question see below If the S2000 K keypad is to be used for visualizing system events and indicating alarms adjust the mechanism of translating system events from the network controller to the S2000 K see below Further in this Manual we describe some procedures of programming an S2000 S2000M S2000L console with the help of PProg Cons...

Страница 32: ...rol specific system partitions and ØRights of the keypad to be used as a device controlling these partitions User rights are defined by means of including users to Access Groups programmed for the console and assigned to these partitions as well as available operations for these partitions namely arming and disarming arming only disarming only or status observing only Users are authenticated in an...

Страница 33: ... first way is to enter a digital PIN code directly from the S2000 K keypad The second way is to present an electronic access device iButton or Prox imity card to a reader connected to another device in the same RS 485 bus such as S2000 4 S2000 2 S2000 KDL etc and then operate the S2000 K to control available partitions The last combined mechanism provides both enhanced security due to using electr...

Страница 34: ...gure 7 Then select the device in the Device Rights window and define its Link a Reader to parameter in the Inspector window specifying the S2000 K in question as the device which is supposed to control partitions after user authentication by means of presenting access device to the reader of the specified S2000 KDL Figure 6 Programming the Mechanism of Translating Events To program the network con...

Страница 35: ...ing pages by arrow buttons on the Quick Access Toolbar or activating the Pages Partitions Partitions menu com mand Add a new partition descriptor by clicking see Figure 7 Figure 7 Then in the bottom window select a group of the zones which will be included to the new partition and drag and drop them on the partition descriptor see Figure 8 and Figure 9 ...

Страница 36: ...Orion ISS www bolid com 36 Figure 8 Figure 9 ...

Страница 37: ...anslated to For do ing so go to the Event Translation tab by pressing or browsing arrow buttons on the Quick Access Toolbar or selecting the Pages Others Event Translation menu command Drag the keypad descriptor in the Devices window and drop them on the device tree in the Event Translation window see Figure 10 Figure 10 ...

Страница 38: ...www bolid com 38 3 The keypad descriptor being selected in the Event Translation window define in the Inspector window the kinds of events which are supposed to be displayed by the keypad see Figure 11 Figure 11 ...

Страница 39: ...9 www bolid com 4 Switch the bottom window of the page to the partition display mode by clicking see Figure 12 or selecting the relevant menu command The list of system partitions will appear in the bottom window Figure 12 ...

Страница 40: ...com 40 5 Drag and drop the partitions which events will be displayed by the keypad from the Partitions win dow on the keypad descriptor in the Event Translation window see Figure 13 Figure 13 6 Now configuring is completed ...

Страница 41: ...S2000 К Maintenance 41 www bolid com MAINTENANCE ...

Страница 42: ...g in use For more about this see Sec tion Programming of this Manual 1 Connecting the S2000 K to a computer with the run UProg Configuration Tool make sure the Display Events option and Indicate Alarms Options are acti vated for the keypad Note that indicating alarms can be enabled only if displaying events is enabled 2 Running the PProg Programming Tool or Orion Soft ware tools make sure that the...

Страница 43: ...ive humidity of 45 to 80 The atmospheric pressure of 630 to 800 mm To inspect the S2000 K keypad do the following Ø Examine the keypad for fouling or mechanical damage than Ø Examine the keypad terminal blocks and tighten loosen screws if necessary and Ø Test S2000 К operability having wired the keypad as shown in Figure 14 The testing procedure has been described below in this Section WARNING Whi...

Страница 44: ...second the keypad LCD dis playing NO RS485 LINE 3 Press any key on the keypad A beep shall follow pressing the key 4 Connect wires of the RS 485 interface bus to the terminal blocks of the S2000 S2000M con sole The console shall indicate having found the device with the current address of the S2000 K followed by resetting this device within a minute 5 Press the keypad tamper switch and keep it pre...

Страница 45: ...S2000 К 9 www bolid com Appendix System Events Displayed by the Keypad LCD ...

Страница 46: ...p Short Failure LTS 14 001 003 A short circuit failure has been detected within the alarm loop 3 which belongs to the device 1 and is included into the partition 14 Fire Signal FS 14 001 003 A fire detector response has been received via the alarm loop 3 connected to the device 1 and in cluded into the partition 14 Intrusion Alarm IA 7 018 003 The alarm loop 3 connected to the device 18 and includ...

Страница 47: ...ress 18 has been re started Power Failure PWRF D018 The input voltage of the device with the network ad dress 18 is out of the normal range Access Granted AG 41 D001 The device with the network address 41 has made a decision to grant access via its protected door to a user having presented the authenticator 41 Access Denied AD 41 D001 The authenticator 41 has been read by a reader of the device wi...

Страница 48: ......

Страница 49: ...HANTABILITY MUST BE BROUGHT WITHIN 12 MONTHS FROM DATE OF ORIGINAL PURCHASE IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some countries do not allow limitation on how long ...

Страница 50: ...4 Pionerskaya Str Korolev 141070 Moscow Region Russia Phone fax 7 495 775 71 55 Email info bolid ru overseas bolid com www bolid com ...

Отзывы: