background image

 

8

5

 

MANUFACTURER WARRANTY 

5.1

 

The  manufacturer  guaranties  the  product  meets  with  technical  requirements  stated 

in the manuals if the user follows the instructions for transportation, storage, installation, and 
usage. 

5.2

 

The  warranty  period  is  18  months  since  putting  the  product  into  operation  but  no 

more than 24 months from the manufacturer’s date of production. 

5.3

 

In  case  of  any  issue  related  to  setting  and  use  of  the  product,  please  contact  the 

technical support: +7 (495) 775-71-55 or e-mail: 

[email protected]

5.4

 

When  the  unit  is  submitted  for  repair,  it  shall  be  mandatory  accompanied  with  a 

report describing the potential failure. 

Claims  shall  be  submitted  to  the  following  address:  NVP  BOLID,  #4  Pionerskaya  Str., 

Korolyov, Moscow Region, 141070, Russia. 

Tel./fax: +7 (495) 775-71-55 

(PBX), 

777-40-20

516-93-72

.

 

E-mail: 

[email protected]

,

 

http://bolid.ru

.

 

6

 

CERTIFICATION 

6.1

 

RIP-12  mod.14  (RIP-12-2/7P2-R)  Battery  Backed  Power  Supply  meets  the 

requirements  of  “Technical  Regulations  on  Fire  Safety  Requirements”  (Federal  Law 
No.123-FZ  of  July  22,  2008,  GOST R 53325-2012)  and  is  covered  by  Conformity 
Certificate No. C-RU.

ЧС

13.

В

.00703. 

6.2

 

RIP-12  mod.14  (RIP-12-2/7P2-R)  Battery  Backed  Power  Supply  meets  the 

requirements 

of 

Technical 

Regulations 

of 

Custom 

Union 

TR CU 004/2011, 

TR CU 020/2011  and  is  covered  by  Conformity  Declaration 

ЕАЭС

 

  RU 

Д

-

RU.

МЛ

66.

В

.02301. 

6.3

 

RIP-12  mod.14  (RIP-12-2/7P2-R)  is  covered  by  the  certificates  of  conformity  of 

transport  safety  technical  arrangements  with  their  functional  properties  No. 

МВД

 

РФ

.03.000035, No. 

МВД

 

РФ

.03.000036, and No. 

МВД

 

РФ

.03.000037, 

issued by  Federal 

Scientific-Production Association “Special Equipment and Communications” of the Ministry 
of Internal Affairs of the Russian Federation. 

6.4

 

Production  of  RIP-12  mod.14  (RIP-12-2/7P2-R)  is  awarded  with  conformity 

certificate GOST R ISO 9001-2015 No. 

РОСС

 RU.

АБ

66.

К

00003. 

7

 

ACCEPTANCE AND PACKAGING CERTIFICATE 

7.1

 

RIP-12  mod.14  (RIP-12-2/7P2-R)  Battery  Backed  Power  Supply  with  the  factory 

number_____________  is  manufactured  and  accepted  as  per  mandatory  requirements  of 
national standards and applicable technical documentation, approved as serviceable. 

7.2

 

RIP-12  mod.14  (RIP-12-2/7P2-R)  Battery  Backed  Power  Supply  is  packaged  by 

NVP Bolid in line with requirements stated in applicable technical documentation. 

Responsible for acceptance and packaging 

 
 
 
 

QCD     ______________________________    ________________________ 

Name 

Date, Month, Year 

Содержание RIP-12

Страница 1: ...t missed battery shutting the battery off in case of its discharge as well as indication of possible RIP faults during operation see Table 2 1 1 6 The RIP provides limiting of the battery charger voltage and current depending on the temperature within the device enclosure 1 1 7 The RIP provides monitoring battery conditions and its connecting circuit by comparing with maximum admissible internal r...

Страница 2: ...messages closed open state of the circuits is at least 3 s The time of delay for messages sent by the relays К1 К3 is 3 s The time of delay for messages Battery Low sent by the K2 relay does not exceed 1 min States of the solid state relay circuits are shown in Table 1 Table 1 Circuit Purpose Contact State К1 Output voltage monitoring In case of normal output voltage1 the contact is closed In case...

Страница 3: ...7 Package 1 pc no battery is included into the delivery 2 OPERATING INSTRUCTIONS 2 1 Safety Precautions 2 1 1 The current carrying circuits connected with mains power 220 V are a source of potential hazard These circuits are covered by a protective housing on the RIP printed circuit board 2 1 2 The safety precautions are as follows 1 The fuse shall always be good and its rating shall be as stated ...

Страница 4: ...n areas of the wires to be connected to the RIP 1 To connect the RIP to mains power 220 V the XT3 terminal block 0 75 2 5 mm2 for stranded wires or 1 2 mm in diameter for solid wires 2 To connect the load 0 5 2 5 mm2 for stranded wires or 0 8 2 mm in diameter for solid wires taking into account the maximum voltage drop on wires at maximum load current the minimum allowable voltage at the load 2 2 ...

Страница 5: ...nutes Operability of the battery charger at least once per 15 minutes Presence of mains voltage No overload and no short circuit conditions at the output 2 4 3 If no mains power is applied then the load starts to be powered by the battery the buzzer periodically emitting low battery warning beeps the POWER LED being off and the BAT LED and 12 V LED illuminating 2 4 4 If the battery voltage has dro...

Страница 6: ...2 Current Conditions of the RIP Indicators Buzzer POWER BAT 12 V TROUBLE green green green amber 1 Mains utility power is starting up no battery is connected ON 0 4 s 8 times 2 Mains power is OK the battery is nor charged OFF 3 s 3 Mains power is OK the battery is charged 4 DC output overcurrent The battery is available ON 15 60 s 2 Hz ON 1 5 s 2 times 5 Mains power is off the battery voltage exce...

Страница 7: ...aking into account the technical guide Maintenance of fire alarm systems and public address and general alarm systems of Types 1 2 in Orion ISS developed by the NVP Bolid Company 4 TROUBLESHOOTING N o Symptom Cause Action 1 The RIP fails to be turned on the mains power is on 1 Blown fuse F1 2 Faulty wiring 3 Long duration overload at the RIP DC output 1 Check the mains power voltage at the ХТ3 ter...

Страница 8: ...13 В 00703 6 2 RIP 12 mod 14 RIP 12 2 7P2 R Battery Backed Power Supply meets the requirements of Technical Regulations of Custom Union TR CU 004 2011 TR CU 020 2011 and is covered by Conformity Declaration ЕАЭС RU Д RU МЛ66 В 02301 6 3 RIP 12 mod 14 RIP 12 2 7P2 R is covered by the certificates of conformity of transport safety technical arrangements with their functional properties No МВД РФ 03 ...

Отзывы: