BN-RITB
January 2004
(Replaces 107.2, 01/04)
Reach-In UnIt cooleRs
Technical Guide
Models TA, TL, C, VA, BBM, BBL, KMK, RAMK, BTO & U
Страница 1: ...BN RITB January 2004 Replaces 107 2 01 04 Reach In Unit Coolers Technical Guide Models TA TL C VA BBM BBL KMK RAMK BTO U...
Страница 2: ...nts Model TA Thin Profile Air Defrost 3 Model TL Thin Profile Electric Defrost 4 Model C High Profile 5 Model VA Vee Aire 6 Models BBM BBL Back Bar 7 Model KMK Kompact Mullion 8 Model RAMK Reverse Air...
Страница 3: ...is at a premium For 35 to 45 F fixtures at 10 to 15 TD applications with 16 hours maximum compressor run time per day Model TA Thin Profile Air Defrost Reach In Unit Cooler Models 43 and 55 use extern...
Страница 4: ...lized expansion valves Table 3 Performance and Electrical Data Diagram 2 Dimensions Table 4 Physical Data Nomenclature TL 12 B G Voltage A 115 1 60 B 208 230 1 60 Thin Profile Electric Defrost Size Vi...
Страница 5: ...the ideal unit for refrigerated reach ins It mounts tothetopoftherefrigeratoranddischargescoldairagainstthe back wall With this air flow pattern the air is not blasted on the product but is diffused...
Страница 6: ...le as a ship loose option Application Model VA is a deluxe unit designed for use in small reach ins back bar and under counter refrigerators and many other applicationswhereasmall compactunitisrequire...
Страница 7: ...lation and performance The BBM medium temperature model is designed for 35 to 40 F fixture temperature with off cycle defrost The unit is designed to operate at 10 to 17 TD and 16 hours per day compre...
Страница 8: ...usedwithairdrawninatthetopanddischarged atthebottom Thisdesignprovidessuperioraircirculationand insures uniform temperature throughout the cabinet Thisversatiledesignisalsoadaptableformountingonthebac...
Страница 9: ...s on salad bars or prep tables It also keep drawer stored product in premium condition An adjustable and detachable air deflector splash protector is included The deflector can be adjusted to direct t...
Страница 10: ...forlargereach inandsmallstep in or walk in coolers Model BTO Twin Flow Reach In Unit Cooler Models 25 35 45 and 55 use external equalized expansion valve Table 15 Performance and Electrical Data Diagr...
Страница 11: ...ose option Application Model U is used wherever a small compact unit is required It can be mounted on the ceiling or wall The model U unit draws air through the front and discharges it out both sides...
Страница 12: ...FAX 770 465 5990 www thecoldstandard com For more information on Bohn refrigeration products contact your Sales Representative or visit us at www thecoldstandard com Since product improvement is a co...