background image

Notice

Every effort was made to ensure that the information in this
guide was complete and accurate at the time of printing.
However, information is subject to change.

Important Safety Information

WARNING:

To Reduce The Risk of Fire Or Electric Shock, Do

Not Expose This Apparatus To Rain Or Moisture.

Always follow these basic safety precautions when installing and
using the unit:

1

.

Read these instructions.

2.

Keep these instructions.

3.

Heed all warnings.

4.

Follow all instructions.

5.

Do not use this apparatus near water. The apparatus shall
not be exposed to dripping or splashing and no objects filled
with liquids, such as vases, shall be placed on the apparatus.

6.  Clean only with dry cloth.
7.

DO NOT block any ventilation openings. Install in 
accordance with the manufacturer’s instructions.

8.

Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including amplifiers)
that produce heat.

9.

Do not defeat the safety purpose of the polarized or
grounding-type plug.  A polarized plug has two blades with
one wider than the other.  A grounding-type plug has two
blades and a third grounding prong. The wide blade, or the
third prong, are provided for your safety. If the provided plug
does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.

1

0. Protect the power cord from being walked on or pinched,

particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.

11

. Only use attachments/accessories specified by the 

manufacturer.

1

2. Unplug this apparatus during lightning storms or when

unused for long periods of time.

1

3. Refer all servicing to qualified service personnel. Servicing is

required when the apparatus has been damaged in any way,
such as power supply cord or plug is damaged, liquid has
been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.

IMPORTANT

C A U T I O N :   TO   P R E V E N T   T H E   R I S K   O F  
ELECTRIC SHOCK,  DO NOT REMOVE COVER
(OR BACK).  NO USER-SERVICEABLE PARTS
INSIDE. 

REFER SERVICING TO QUALIFIED

PERSONNEL.

The lightning flash with arrowhead 
symbol, within an equilateral triangle, is
intended to alert the user to the 
presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be
of sufficient magnitude to constitute a risk
of electric shock to persons.

The exclamation point within an 
equilateral triangle is intended to alert the
user to the presence of important operating
and maintenance (servicing) instructions in
the literature accompanying the appliance.

Содержание VMIX

Страница 1: ...Power Vector Mixer Model VMIX Installation and Use Manual 2005 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 2134 01C 1204 ...

Страница 2: ...y If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused fo...

Страница 3: ...Balanced Output 6 Remote Volume Control 6 Bridging 6 Mute Control 7 System Expansion of Power Vector Mixers 7 OPERATION 8 9 Front Panel Controls Indicators 8 Input Volume Controls and Signal Clip Indicator 8 Bass and Treble Controls 8 Master Volume Control 8 Average Peak Switch LED Output Meter 8 Power Switch Power Indicator 8 Rear Panel Controls 9 Balanced Out Switch 9 Other Controls 9 Tone Contr...

Страница 4: ...reble Control Controls the amount of cut or boost of treble frequencies above 10 kHz 4 LED Output Meter An 11 segment LED output level meter monitors the output level of the mixer 5 Master Volume Control Controls overall level of mixed input signals 6 Power Indicator An LED indicates AC power status 7 Bass Control Controls the amount of cut or boost of bass frequencies below 100 Hz 8 Average Peak ...

Страница 5: ...e bay 6 that allows roll off of frequencies below 125 Hz 6 Tone Control Bypass Switch A slide switch located in module bay 6 that allows the effects of the bass and treble controls to be bypassed 7 AC Line Cord and Circuit Breaker A grounded 3 wire AC line cord provides power to the mixer and is protected by a resettable circuit breaker 8 Balanced Out Level Switch Three position slide switch that ...

Страница 6: ...e Installation Eight module bays are available to accept Bogen s new advanced input modules Module bays 7 8 can also accommodate Bogen s new advanced output modules thereby allowing users to customize the mixer to suit the needs of the installation The bays will not accept Bogen s older style plug in modules Before installing a module read the instructions included with the module and make the des...

Страница 7: ...included so that the input function of the module bay is not lost when an output module is installed Input Modules Functionality The Power Vector mixer accepts Bogen s new advanced input modules which provide a wide range of input types allowing the mixer inputs to be custom configured in both type and number for a particular application Input modules can be installed into any of the 8 module bays...

Страница 8: ...l of the MasterVolume control The impedance of the shorting connections must be less than 100 ohms in order to operate the control The Bogen Remote Volume Control Panel Model RVCP provides a simple and elegant means of remote control Alternatively a SPDT spring loaded center off switch or two SPST push button switches can provide the necessary contacts for remote control Bridging This connector ma...

Страница 9: ...rol lines it is possible to connect two or more Power Vector units into a larger integrated system Wire the bridging jack and mute control lines as shown in the diagrams for bridging either 2 or 3 units together The overall system gain of PowerVector products dimin ishes when they are bridged because each unit s mix bus loads down the other product s bus When bridging two PowerVector products the ...

Страница 10: ...e The bass control has a cut boost range of 10 dB at frequencies below 100 Hz Master Volume Control The overall volume level of the mixer is set by a MasterVolume control The MasterVolume control is motorized and can be controlled by man ually adjusting the knob or by a remotely mounted control station Connections and requirements for the remote control station are described in the Connections sec...

Страница 11: ... andTreble controls is located on the back plane of module bay 6 It is sometimes desirable to bypass the tone controls when other forms of system equalization are used A screwdriver can be used to set the switch The switch must be set before a module is installed in this bay Low Cut Switch The Power Vector mixer provides a low cut filter that rolls off frequen cies below 125 Hz The slide switch fo...

Страница 12: ...Block Diagram 10 ...

Страница 13: ... minimum Low Cut Frequency 125 Hz 6 dB octave Signal Clip Indicator Signal Detect Threshold 10 mV output of module Signal Indicator Hold Time 50 mS green indicator Clip Detect Threshold 6V output of module Clip Detect Hold Time 50 mS red indicator Output Impedance Balanced 50 ohms 4 dBµ 600 ohms 10 dBµ 5 ohms 50 dBµ Unbalanced 100 ohms Power Consumption 21 watts AC Power Receptacle 500 watts maxim...

Страница 14: ...eration of motorized master volume control Fits in standard single gang electrical box Decora style cover plate PVSC Power Vector Security Cover Prevents tampering with system settings Power and meter switches accessible Simple installation PVMC Power Vector Module Cover Prevents tampering with module controls Adaptable for different module types Covers unused module slots A variety of accessories...

Страница 15: ... PARTICULAR PURPOSE ARE HEREBY DIS CLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NO...

Страница 16: ...50 Spring Street Ramsey NJ 07446 U S A Tel 201 934 8500 Fax 201 934 9832 www bogen com ...

Отзывы: