Specifications subject to change without notice.

© 2009 Bogen Communications, Inc.

All rights reserved.    54-5810-05C  1206

BPA60

Power Amplifier

Installation & Use Manual

Rated Output Power:

60 watts 

Total Harmonic Distortion:

Less than 2% from 50 Hz to 15 kHz

Frequency Response:

-2 dB, 20 Hz to 20 kHz

Input Sensitivity:

High-impedance, 300mV; low-impedance balanced (with optional 
transformer), 75mV

Hum and Noise:

85 dB below rated output

Output Loads:

8-ohm/25V, 16-ohm, 25V CT, 70V

Output Regulation:

Better than 2 dB from no load to full load

Input Impedances:

High-impedance, 50k ohms unbalanced; low-impedance, 600 ohms, 
balanced (with optional transformer)

Lo-cut Filter:

-10 dB at 100 Hz (switch-selectable)

Controls and Indicators:

Front Panel

— Illuminated on/off power switch

Rear Panel

— Input level control, circuit breaker reset, lo-cut filter switch

Power Consumption:

120V AC, 60 Hz, 180W at full rated output

Thermal Emissions (full power):

204.9 BTU/hr.

Overload Protection:

Transient protection diodes, electrical circuit breaker, 

thermostat

Operating Temperature Range:

-4° F to 131° F (-20° to +55° C) at rated output

Auxiliary Receptacle (not switched): 

Three-wire grounded*, 300W maximum, 2.5A (internally fused)

Dimensions:

15-1/4"W x 3-1/2"H x 8-1/4"D

Finish:

Black

Product Weight:

17 lbs.

Approvals:

Listed to UL Standard 60065 for US and Canada

Accessories:

Model TL600, 600-ohm line-matching transformer; 
Model TL100, 1:1 ratio transformer;
Model RPK53 rack panel brackets

*This receptacle will be grounded only if the power amplifier has been grounded properly.

Technical

Specifications

Содержание BPA-60

Страница 1: ...tch selectable Controls and Indicators Front Panel Illuminated on off power switch Rear Panel Input level control circuit breaker reset lo cut filter switch Power Consumption 120V AC 60 Hz 180W at full rated output Thermal Emissions full power 204 9 BTU hr Overload Protection Transient protection diodes electrical circuit breaker thermostat Operating Temperature Range 4 F to 131 F 20 to 55 C at ra...

Страница 2: ...radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your o...

Страница 3: ...g 2 on back page on the printed circuit board If an unbalanced input is required connect a jumper from the GND terminal to an adjacent input terminal Bridging Input Caution To avoid electric shock be sure to disconnect AC Power Cord before removing the cover of the amplifier unit Warning DO NOT perform any function requiring the removal of the cover of the amplifier unless you are qualified to do ...

Страница 4: ...State to State Products that are out of warranty will also be repaired by the Bogen Factory Service Department same address as above or call 201 934 8500 The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department All shipping charges in addition to parts and labor charges will be at the owner s expense All returns require a Return ...

Отзывы: