FOCUS
1.3
Display information
Page 12
BOGE FOCUS compressor control for piston compressors
Set date / time
In order to set both time and date, keep the
ENTER key
on the menu page
"date / time" for three seconds.
The cursor jumps to the time display and the digits of the hour display start
blinking.
Use
keys
/
to set digits.
With the
ENTER key
the input is acknowledged and the cursor moves to
the next field. Proceed the same way with all other place values until all values
are correctly adjusted. In case a value has to remain unchanged just actuate
the
ENTER key
, to jump to the next value.
To leave the time adjustment, actuate
ENTER key
until none of the place
values is blinking any longer. Actuate
key
to reach the previous page or ac-
tuate the
key
to go to the next page.
If the
INFO key
is actuated while adjustments are made to the real-time-
clock, this setting is left without accepting the parameterized changes.
Display of version
The version display can be reached in the menu by pressing the
/
keys
.
Here the name of the control, the software number and the manufacturer are
displayed.
If the
key
is pressed now you get to the
Module Info
display.
Here the addresses and the installed software versions of the connected mod-
ules are shown.The first display refers to the basic module (Address: 0), all
other connected modules can be displayed by actuating the
/
keys
.
If the display of a module is flashing the communication with this module is
faulty.
You can leave Module Info by actuating the
INFO key
.
Module
Address
Position of rotary
switch
Basic module
0
--
TAN
1
--
FC (frequency converter) module
10
0
FC module for connection of soft starters
11
1
System pressure module
12
2
Dryer module
20
--
RS485 module
30
0
Analog output module
50
0
Note!
Relay modules are not displayed.