BOGE Operating instructions for C 16 N...C 30 N, C 16 F N...C 30 F N series screw compressors
Page 59
Maintenance
6.3
Maintenance work compressor
Filling with new oil:
–
Fill up to the edge of the thread of the filling socket (max.) (procedure as
described above).
–
Conduct trial run.
–
Check the oil filters and oil separators for leaks and tighten by hand,
if necessary.
–
Check oil level (procedure as described above).
Top up oil losses, if any.
Flushing the oil circuit
Flushing the oil circuit with clean oil becomes necessary:
–
When the oil is excessively soiled.
–
Prior to changing the oil type.
Cleaning the
compressed air/oil
cooling unit
Cleaning:
–
After 1500 operating hours, however, at the latest after one year.
WARNING!
Always fill with the same oil type as previously used. Never mix different oil
types and brands.
The oil circuit must be flushed prior to changing the oil type.
WARNING: Risk of injury!
Actuate emergency-stop switch/button, open mains disconnecting device
and secure by means of lock out tag out.
WARNING!
Detailed information as to the flushing with BOGE oils you can obtain from
the following service number:
Telephone: +1-770-874-1570
Telephone: +49 5206 601-140
NOTICE!
The service life of the compressed air/oil cooling unit depends on the degree
of soiling (dust, oil vapour) of the suctioned cooling air. Extreme external
soiling of the cooling unit leads to an increased temperature in the oil circuit.