Setting Parameters
5.2
Changing Individual Parameters
1. Unlock the code-protected parameters for the compressor servicing inter-
val using
code 111
, as described under
.
The current start value for the countdown counter flashes on the seven-
segment display.
2.
Press the Info key
until the desired value is displayed.
3.
Press the Enter key
.
The main display reappears on the control.
The previous value is overwritten.
The changed value is set.
Motor Servicing Inter-
val: Restart the Counter /
Change the Start Value
This function is used to signal in advance the pending servicing of the motor.
The hours until the next motor servicing interval count down from a start value
(remaining hours). When the value reaches 0, the control outputs a mainte-
nance message. After servicing, the countdown counter must be manually
reset to the start value.
To
restart
and reset the countdown counter to the start value until the next
motor servicing interval:
1. Unlock the code-protected parameters for the motor servicing interval
using
code 222
, as described under
"Unlocking Code-protected Param-
.
The current start value for the countdown counter flashes on the seven-
segment display.
2.
Press the Enter key
.
The main display reappears on the control.
The servicing interval countdown counter has been reset to the start
value and restarted.
CAUTION
Compressor Damage
If the maximum start value (21,000 h) is set, the countdown counter stops
and the compressor servicing interval function is deactivated, meaning that
urgently required servicing work may be overlooked.
Please consult BOGE Product Support prior to setting the highest value.
CAUTION
Compressor Damage
If the servicing interval countdown counter is not restarted, urgently
required servicing work can be overlooked.
After all servicing work, the respective countdown counter must be
manually reset to the start value.