RapidFISH
Models 240200 and 240200-2
Operating Instructions
Страница 1: ...N2400362 Rev 1 04 16 RapidFISH Models 240200 and 240200 2 Operating Instructions...
Страница 2: ...4 5 0 Operation 5 5 1 Turning the Unit On 5 5 2 Modes of Operation 6 6 0 Calibration 7 7 0 Technical Specifications 9 8 0 Additional Accessories Available for Purchase 10 9 0 Fault Diagnosis 10 10 0...
Страница 3: ...hat it is difficult to operate the disconnecting device Use only as specified by the operating instructions or the intrinsic protection may be impaired After transport or storage in humid conditions d...
Страница 4: ...ir replacement for shipping damages must be coordinated through the carrier Complete and return the Warranty Registration Card or you may also complete this Warranty Card online at www boekelsci com T...
Страница 5: ...e or decrease the selected variable Press and hold for rapid change E LCD Display Shows set temperature program number actual temperature time remaining and heating indicator F When the unit is in ful...
Страница 6: ...time and temperature values to be run sequentially 5 2 2 The Program key cycles through the different programs S1 S2 S3 HT S1 and so forth 5 2 3 In HT mode the RapidFISH will hold temperature at the d...
Страница 7: ...ay the word OFF 5 2 4 6 Times can be adjusted from 000 01 to 999 59 mmm ss 5 2 4 6 1 S2 and S3 can be set to hold indefinitely in the program by adjusting the time value down to the value below 000 01...
Страница 8: ...key to confirm temperature reading 6 4 Allow the unit 60 minutes to achieve new calibration setpoint of 60 0 C Once the 60 minutes have elapsed the unit will beep once and flash the 60 0 C text on the...
Страница 9: ...with IEC 664 For operation at altitudes of up to 6500 feet 2000 meters Temperature Range Ambient 5 0 C to 75 C Stability 0 2 C Accuracy 0 5 C Temperature Display Resolution 0 1 C Supply Ratings Model...
Страница 10: ...d a Actual temperature is higher than Set temperature b Temperature control circuit fault c Circulation Fan failure a Check set temperature b Have unit checked by a competent service person c Have uni...
Страница 11: ...t if hazardous material is spilled onto or into the equipment no decontamination or cleaning agents are used which could cause a hazard as a result of a reaction with parts of the equipment or with ma...
Страница 12: ...w to adjust the contrast up or down respectively Care should be taken to avoid adjusting contrast so far in one direction that the text on the display becomes unreadable 12 0 Warranty When used in lab...
Страница 13: ...l Scientific prior to receiving the RMA number Please consult the manufacturer or his agent if there is any doubt about the compatibility of decontamination or cleaning agents Please be sure to mark t...