background image

 

 

 

BodyGuard 

SAFETY SOLUTIONS 

-Tag 

®

 

 

Driver Awareness System

 

  

 

BodyGuard Safety Solutions—A division of Orbit Communications Pty Ltd          Install Guide rev r1.11        

Page 

2

 

Introduction 

This Guide provides information to assist with installation and use of the BodyGuard® i-Tag® proximity 
detection and warning system. 

The document begins with an overview of the system and then describes the wiring connections for 
both single sensor and dual sensor systems. 

An  explanation  is  given  for  installation  and  running  the  simple  configuration  utility  that  enables 
changes to the detection zone distances and speaker volume using a Bluetooth connection between 
computer BodyGuard® systems. 

Overview 

The BodyGuard® system improves safety by increasing driver awareness when pedestrians are too 
close to the vehicle. The system comprises a Cab Alert unit, Speaker and one or more sensor units. 

The Sensor Unit receives information from pedestrian “Tag” devices, process and transfer information 
to the Cab Alert unit. 

The Cab Alert Unit processes information from all sensors and determines whether a Tag detection 
has  occurred  within  the  detection  zone  of  any  Sensor  unit  fitted.  The  Cab  Alert  unit  provides  an 
Audible alarm (alert followed by human voice notification) as well as visual warning. In addition to the 
Alarm  functions,  the  Cab  Alert  manages  installation  and  removal  of  sensor  units,  storage  of  all 
detection and system events and facilitates Bluetooth communication between the Cab Alert unit and 
computer.  

 

 

Содержание i-Tag

Страница 1: ...BodyGuard SAFETY SOLUTIONS Tag Driver Awareness System BodyGuard Safety Solutions A division of Orbit Communications Pty Ltd Install Guide rev r1 11 Page 1 Installation Guide...

Страница 2: ...uter BodyGuard systems Overview The BodyGuard system improves safety by increasing driver awareness when pedestrians are too close to the vehicle The system comprises a Cab Alert unit Speaker and one...

Страница 3: ...to overall shielding The recommended maximum cable length between the Cab Alert unit and a sensor unit is 200m The 4 core cable is terminated at each end using M12 Male circular plugs The cable wiring...

Страница 4: ...nfastened hold knurled plastic ring near metal ring with one hand and turn plastic body of plug anti clockwise with other hand IMPORTANT Be careful to ensure correct wiring of plug The signals are con...

Страница 5: ...he vehicle electrical system Sensor units receive power from the Cab Alert connector Power Cable connections Pin 1 12V DC Power Supply Input Brown Pin 2 Ignition Sense White Pin 3 Switched output Blue...

Страница 6: ...TY SOLUTIONS Tag Driver Awareness System BodyGuard Safety Solutions A division of Orbit Communications Pty Ltd Install Guide rev r1 11 Page 6 12 24V DC supply with Data Logging Higher than 24V DC supp...

Страница 7: ...BodyGuard SAFETY SOLUTIONS Tag Driver Awareness System BodyGuard Safety Solutions A division of Orbit Communications Pty Ltd Install Guide rev r1 11 Page 7 Higher than 24V DC supply with logging...

Страница 8: ...pen Drain floating output This output pulls to ground whenever the alarm is active This low current output less than 100mA capacity controls an external relay that can switch other equipment or device...

Страница 9: ...m left below the enclosure to enable cables to exit the enclosure without excessive bending The supplied pivot mounting bracket enables the cab alert unit to be mounted in any orientation and then rot...

Страница 10: ...uniform zone is required These characteristics of the Sensor detection zone shape can be used to advantage in various applications For instance a large vehicle may require long distance at front and...

Страница 11: ...s perpendicular to the long side of the sensor unit while the shorter side is at the sides looking into the end of the sensor unit The shorter side may be around 80 85 of the long side distance The im...

Страница 12: ...ection zone The long axis is up and down while the short axis is around the vehicle This orientation produces the most uniform almost circular pattern however the maximum range in this orientation may...

Страница 13: ...tions Pty Ltd Install Guide rev r1 11 Page 13 Front and Rear Horizontal Sensor Orientation The example below illustrates how multiple sensors provide extended range at front and rear of larger vehicle...

Страница 14: ...ications Pty Ltd Install Guide rev r1 11 Page 14 Front and Rear Vertical Sensor Orientation The example below illustrates how multiple sensors provide extended range at front and rear of larger vehicl...

Страница 15: ...red until desired range achieved Do NOT open lid when water can enter and ensure lid fastened securely after distance adjusted Distance Switch 1 Switch 2 Switch 3 Switch 4 3 OFF OFF OFF OFF 4 5 ON OFF...

Страница 16: ...olume setting Configuration software Refer to configuration and log management device User guide System Operation Power Up At power up the system will flash warning LEDs turn on POWER LED and provide...

Страница 17: ...advise Speaker Muted and the repeating siren will cease The LEDs will remain flashing as long as the Tag is still in the detection zone If the Tag leaves the zone OR another Tag enters then the alarm...

Страница 18: ...damages of any kind resulting from errors in data transmitted or received using the BodyGuard systems or for the failure of the BodyGuard system to transmit or receive such data Do not operate the Bo...

Страница 19: ...placed with specified type and rating only Ensure power removed from fuse before attempting to replace Ignition switched OFF Ensure cause of fuse blowout fixed before replacing fuse Ensure Power suppl...

Страница 20: ...o guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equi...