background image

SH042-1 User Manual for BodiTrak LT  V1.5, 25 Jan 2019                                                                                   

1

 

BodiTrak Technical Support

800-847-3157

 

 

 

 

 

User Manual 

For  

BodiTrak LT 

 

 

 

 

Table of Contents 

1.0  Introduction                                                                                2 

2.0  Compliance                                                                                2 

3.0  Warnings                                                                                    4 

4.0  Installation                                                                                  5 

5.0  Using the BodiTrak LT System                                                   7 

6.0  Care of the BodiTrak Mat                                                          14 

7.0  Cleaning the BodiTrak Mat                                                        14 

 

 

 

 

 

Содержание LT System

Страница 1: ... BodiTrak Technical Support 800 847 3157 User Manual For BodiTrak LT Table of Contents 1 0 Introduction 2 2 0 Compliance 2 3 0 Warnings 4 4 0 Installation 5 5 0 Using the BodiTrak LT System 7 6 0 Care of the BodiTrak Mat 14 7 0 Cleaning the BodiTrak Mat 14 ...

Страница 2: ... de la classe A est conforme a la norme NMB 003 du Canada 2 2 United States The FCC has specified in 47 CFR 15 105 that the following notice be brought to the attention of the users of this product This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against ha...

Страница 3: ...to comply with CAN CSA C22 2 No 60601 1 2008 ANSI AAMI ES 606011 2005 A2 2010 EN 60601 1 2006 A11 2011 IEC 60601 1 2 2007 edition 3 2 5 The following table shows classifications and environmental parameters for the BodiTrak pressure mat Medical Device Type Class 1 with measurement function Class for electromagnetic compatibility Class A Degree of protection against electric shock Type B Applied Pa...

Страница 4: ...r help 3 3 When external equipment such as a computer is connected to this equipment it should comply with EN 60950 for IT equipment or the EN 60601 1 1 series for medical electrical equipment Equipment not complying with EN 60601 1 1 shall be kept outside the patient environment as defined in the standard at least 1 5 m from the patient or the patient support 3 4 Electrical interference such as e...

Страница 5: ... i Sensor mat with USB cable and built in Wi Fi or Sensor mat with micro USB cable ii Optional DataPort wireless module iii Quick Set Up Guide in PDF iv User Manual in PDF 4 3 Software Installation Instructions 1 Using the tablet go to Google Play Store 2 In the search box type BodiTrak 3 Choose BodiTrak LT 4 Tap Install button 5 Tap Open button 6 If prompted for permissions enable location and st...

Страница 6: ... choose DataPort then go to your device s Wi Fi settings select the BodiTrak s 2 or the Data Port s SSID you wish to connect to and input the provided password BodiTrak s 2 SSID and password can be found on the tag attached to the USB cable Data Port s SSID and password is shown on a tag attached to your module 11 If the blue mats appear on the User Interface the connection was successful 12 If yo...

Страница 7: ... system has 2 modes On the Go scanning and Multiple Comparison You can switch back and forth by tapping the square in a square icon 5 5 1 On the Go Scanning Mode This mode is intended to provide a quick and easy way to assess a person s situation on a surface over time The scanning starts as soon as you plug in the sensing mat and select start mapping The display is divided to show two seat images...

Страница 8: ...ge A value of 50 or more is indicative of a potential risk of skin trauma Peak Pressure Index The average of the highest recorded pressure values within a 9 to10cm2 area the contact area of an IT PPI is a better comparative bench mark than average seat pressures Sensing Area in2 The area of the mat the client is resting on which is displaying above the minimum setting e g 5 mmHg Generally you want...

Страница 9: ...test change in pressure over the surface of the seat are displayed as hotter colors It is believed that where pressures change quickly from one location to another there is a risk of shear occurring to tissue a start timer and time indicator that can sound an alarm at a chosen time to remind a client to shift their weight a Reset Risk button used to reset the risk display On the top of the display...

Страница 10: ...rate time for demo mode Set higher to display quicker CENTER OF PRESSURE Center of Pressure On or off Shows center of pressure on mat Center of Pressure Tail Length Can set from zero to several seconds OTHER SETTINGS Sensing Area Metric Units On or off Orientation Portrait On or Off APPLICATION INFORMATION Version Displays Current Version A Snapshot icon Figure 3 which allows you to take a screens...

Страница 11: ...g the image sends it to the tablet s document folder Figure 4 entering user information A circular arrow icon which will rotate the view of the mat 180 degrees 5 5 2 Multiple Comparison Mode The Multiple Comparison is a comparison tool for considering solutions to seating issues A series of up to four images are taken in sequence to allow for side by side comparison To begin the comparison wizard ...

Страница 12: ...ure 6 Multiple Comparison user interface When the Start Comparison button is touched an information dialogue box will appear as shown in Figure 7 This will allow the user to input relevant data to identify the images later Figure 7 User information dialogue box When the user information is entered and OK is selected the scan page returns as shown in Figure 8 Figure 8 Multiple Comparison page ...

Страница 13: ...at this step up to three more times If you wish to stop before all four screenshots are taken simply tap the Finish button After you have taken the snapshots a screen will appear showing all of the images together Figure 9 You can select any one of the images to see an enlarged view Figure 9 Multiple Comparison Report display A pdf file is automatically generated The image can be located by going ...

Страница 14: ... USB cable do not remove it It is the operator s responsibility to ensure all cables are in good condition inspect all cables for nicks or abrasions prior to each use 7 CLEANING THE BODITRAK MAT BodiTrak pressure sensing mats are typically covered in polyurethane coated nylon Lycra stretch fabric Unplug the mat before cleaning For daily cleaning we recommend wiping down with a damp not wet cloth u...

Отзывы: