201 Northfield Road | Northfield Illinois, 60093, U.S.A. | Phone 773.478.3515 | www.bodine-electric.com | [email protected]
07400213 Rev.C
5.25 REF.
7.12 REF.
1.00 TYP.
.38 TYP.
.38 TYP.
1.00 TYP.
.28 I.D.
HOLE TYP.
.12 R.
TYP.
72” REF.
3.08 REF
.
6.35 REF.
.109
MIN.
3.63 REF.
3.92 REF
.
SPEED
0
ON
O F
100
POWER
R
B O D I N E
ELECTRI C
COMPANY
wp
w m
C motor speed contro
DC
l
SPECIFICATIONS
Input Voltage
115 VAC ±10%, 50/60 Hz, single phase
Maximum Input Current, Continuous
Model 0790
2.5 Amps RMS
Model 0791
5.7 Amps RMS
Output Voltage
0-130 VDC
Ambient Temperature
0-40° C.
Maximum Output Current, Continuous
Model 0790
2.00 Amps DC*
Model 0791
3.20 Amps DC
Maximum Output Current, Peak
Model 0790
2.20 Amps DC
Model 0791
5.00 Amps DC
Speed Regulation
1% of rated speed
obtainable with most motors
Acceleration/Deceleration Time
Adjustable, 0.1-15 seconds
Means for Speed Adjustment
10K Ohm potentiometer
Means for Drive Inhibit
switch closure
Diagnostics
green power LED, red current limit LED
* Thermal rating only. Actual max. continuous output current is 1.25 Amps.
INSTALLATION
WARNING:
This control should only be installed by a qualified person familiar with
its operation and associated hazards. The National Electrical Code (NEC), local
electrical and safety codes, and when applicable, the Occupational Safety and
Health Act (OSHA) should be observed to reduce hazards to personnel and property.
FIGURE 1–
Control mounting dimensions
Instructions for Installation and Operation
Type WPM Filtered PWM Speed Controls for Permanent Magnet DC Brush Motors
• Models 0790 & 0791, NEMA 1 enclosure
Step 1: Mounting the Control
The control may be mounted using any two or all four mounting holes. The mounting
holes have clearance for 1/4-20 or M6 screws.
Step 2: Preliminary Setup
HORSEPOWER & ACCELERATION SELECTOR SWITCHES–
Control models 0790 and
0791 are packaged with the enclosure cover unattached. Remove the cover to set
the horsepower and acceleration selector switches.
Figure 4
shows the location of
a bank of 8 dip switches. Set switches 1 through 6 to match the type, speed, and
current ratings on the Bodine motor nameplate per
Figure 2
(consult Bodine on
settings for non-Bodine motors). Set switches 7 and 8 to select the acceleration/
deceleration time range per
Figure 3.
Step 3: Electrical Connections
The enclosure cover must be removed as shown in
Figure 4
to make the electrical
connections.
WARNING–
All parts of the circuit operate at voltages capable of causing
serious injury or death.
WARNING–
The AC power line to the control should be the last connection made.
CAUTION–
The control board signal common is not at ground potential. Any
external signal or equipment connected to the control must be electrically
isolated from ground.
INHIBIT SWITCH (OPTIONAL)–
A mechanical switch or relay with contacts rated
for low voltage may be connected to terminals “H1” and “H2”. With the switch
open, the motor will run. With the switch closed, the motor will coast to a stop.
WARNING–
The inhibit switch should not be used to disable motor or control
when servicing these or driven equipment. Disconnect the AC power instead.
FIGFIGURE 2–
Setup of Dip Switches 1 through 6
Control
Motor Ratings
Control Setup
Motor
Type
Armature
RPM@
130V
1
Motor Rated
Amps
2
Motor HP
Dip
Switches
On
Peak
Output
Amps
3
Continuous
Input
Current
4
Model
0790
24A0
2500
0.22
1/50
Consult Bodine Factory
24A2
2500
0.3
1/29
1,2
0.6
0.8
24A4
2500
0.48
1/17
1,2,3
1.0
1.1
24A4
2500
.56 | .81
1/23 | 1/11
3,5,6
1.2
1.4
33A3
2500
.78 | 1.0
1/16 | 1/8
2,4,5,6
2.1
1.9
33A3
2500
0.74
1/12
3,5,6
1.2
1.4
33A3
2000
0.71
1/12
3,5,6
1.2
1.2
33A5
2500
0.91
1/8
2,4,5,6
2.1
1.9
42A3
2500
1
1/8
2,4,5,6
2.0
2.0
42A4
2000
1.3
1/6
1,2,4,5,6
2.2
2.5
Model
0791
24A4
11500
1.1
1/7
3
5
1.7
1.9
33A3
2500
0.74
1/12
1
1
1.4
33A3
2500
.78 | 1.0
1/16 | 1/8
3
1.7
1.9
33A3
2000
0.71
1/12
1
1
1.4
33A5
2500
1.4(1.3) | 1.8(1.7) 1/8 | 1/4
2,3
2.0
2.5
33A5
2000
1.4
1/6
3
1.7
1.9
33A5
2500
0.91
1/8
3
1.7
1.9
33A7
2500
1.8 | 2.4
1/6 | 1/3
3,5
4.1
3.6 | 4.8
42A3
2500
1
1/8
1,3
1.9
2
42A4
2000
1.3
1/6
2,3
2
2.5
42A5
2500
1.9 | 1.8
3/16 | 1/4
3
1.7
1.9
42A5
2500
1.8
1/4
3,5
4.1
3.6
42A5
2500
2.7
1/3
3,5
4.1
4.8
42A7
2500
2.3
1/3
2,3,5
4.9
4.0
42A7
2500
3.4
1/2
2,3,5
5.0
5.7
42A7
2500
3.3
7/16
2,3,5
5.0
5.7
FIGURE 3–
Setup of dip switches 7 and 8
Switches
Acceleration/Deceleration Time Range (seconds)
6
7
8
ACC pot fully CCW (factory setting)
ACC pot fully CW
Off
Off
.1
.3
Off
On
.5
2.0
On
Off
3.5
12.0
On
On
4.0
15.0
1. For armature speed of a geared motor, multiply the output speed at the driveshaft by the
gear ratio.
2. If the user desires to install their own armature fuse on the control output to protect the motor
from continuous overloads, base fuse ratings on the motor rating in this column.
3. Peak current available with TORQ pot in fully CW position (factory setting). This current exceeds
the continuous rating of the motor and is for intermittent overload conditions only.
4. Use this column for sizing a line fuse on the control input.
5. The REG potentiometer must be turned fully CCW (off) for high-speed type 24ABEPM motor.
6. Time for voltage across A1 and A2 to ramp up to 130 V when speed pot is turned from 0 to 100;
or to ramp down to 0 V when it is turned from 100 to 0. The time for a motor to accelerate from 0
to 2500 rpm or decelerate from 2500 to 0 rpm is dependent on motor size and loading conditions.
RoHS
COMPLIANT