SPECIFICATIONS
Input Voltage

115 VAC ±10%, 50/60 Hz, single phase

Maximum Input Current, Continuous

  Model 0790

2.5 Amps RMS

  Model 0791 

5.7 Amps RMS

Output Voltage

0-130 VDC

Ambient Temperature

0-40° C.

Maximum Output Current, Continuous

  Model 0790

2.00 Amps DC*

  Model 0791 

3.20 Amps DC

Maximum Output Current, Peak

  Model 0790

2.20 Amps DC

  Model 0791 

5.00 Amps DC

Speed Regulation 

1% of rated speed  

obtainable with most motors

Acceleration/Deceleration Time

Adjustable, 0.1-15 seconds

Means for Speed Adjustment

10K Ohm potentiometer

Means for Drive Inhibit

switch closure

Diagnostics

green power LED, red current limit LED

* Thermal rating only. Actual max. continuous output current is 1.25 Amps.

 INSTALLATION

WARNING:

 This control should only be installed by a qualified person familiar with 

its operation and associated hazards. The National Electrical Code (NEC), local 

electrical and safety codes, and when applicable, the Occupational Safety and 

Health Act (OSHA) should be observed to reduce hazards to personnel and property. 

FIGURE 1–

Control mounting dimensions

Instructions for Installation and Operation

Type WPM Filtered PWM Speed Controls for Permanent Magnet DC Brush Motors 

• Models 0790 & 0791, NEMA 1 enclosure

Step 1: Mounting the Control

The control may be mounted using any two or all four mounting holes. The mounting 

holes have clearance for 1/4-20 or M6 screws.

Step 2: Preliminary Setup

HORSEPOWER & ACCELERATION SELECTOR SWITCHES–

Control models 0790 and 

0791 are packaged with the enclosure cover unattached. Remove the cover to set 

the horsepower and acceleration selector switches. 

Figure 4

 shows the location of 

a bank of 8 dip switches. Set switches 1 through 6 to match the type, speed, and 

current ratings on the Bodine motor nameplate per 

Figure 2

 (consult Bodine on 

settings for non-Bodine motors). Set switches 7 and 8 to select the acceleration/

deceleration time range per 

Figure 3. 

Step 3: Electrical Connections

The enclosure cover must be removed as shown in 

Figure 4 

to make the electrical 

connections.

WARNING–

All parts of the circuit operate at voltages capable of causing 

serious injury or death.

WARNING–

The AC power line to the control should be the last connection made.

CAUTION–

The control board signal common is not at ground potential. Any 

external signal or equipment connected to the control must be electrically 

isolated from ground.

INHIBIT SWITCH (OPTIONAL)–

A mechanical switch or relay with contacts rated 

for low voltage may be connected to terminals “H1” and “H2”. With the switch 

open, the motor will run. With the switch closed, the motor will coast to a stop.

WARNING–

The inhibit switch should not be used to disable motor or control 

when servicing these or driven equipment. Disconnect the AC power instead.

FIGFIGURE 2–

Setup of Dip Switches 1 through 6

Control

Motor Ratings

Control Setup

Motor 

Type

Armature 

RPM@ 

130V

1

Motor Rated 

Amps

2

Motor HP

Dip 

Switches 

On

Peak 

Output 

Amps

3

Continuous 

Input 

Current

4

 

Model 

0790 

24A0

2500

0.22

1/50

Consult Bodine Factory

24A2

2500

0.3

1/29

1,2

0.6

0.8

24A4

2500

0.48

1/17

1,2,3

1.0

1.1

24A4

2500

.56 | .81

1/23 | 1/11

3,5,6

1.2

1.4

33A3

2500

.78 | 1.0

1/16 | 1/8

2,4,5,6

2.1

1.9

33A3

2500

0.74

1/12

3,5,6

1.2

1.4

33A3

2000

0.71

1/12

3,5,6

1.2

1.2

33A5

2500

0.91

1/8

2,4,5,6

2.1

1.9

42A3

2500

1

1/8

2,4,5,6

2.0

2.0

42A4

2000

1.3

1/6

1,2,4,5,6

2.2

2.5

Model

0791

24A4

11500

1.1

1/7

3

5

1.7

1.9

33A3

2500

0.74

1/12

1

1

1.4

33A3

2500

.78 | 1.0

1/16 | 1/8

3

1.7

1.9

33A3

2000

0.71

1/12

1

1

1.4

33A5

2500

1.4(1.3) | 1.8(1.7) 1/8 | 1/4

2,3

2.0

2.5

33A5

2000

1.4

1/6

3

1.7

1.9

33A5

2500

0.91

1/8

3

1.7

1.9

33A7

2500

1.8 | 2.4

1/6 | 1/3

3,5

4.1

3.6 | 4.8

42A3

2500

1

1/8

1,3

1.9

2

42A4

2000

1.3

1/6

2,3

2

2.5

42A5

2500

1.9 | 1.8

3/16 | 1/4

3

1.7

1.9

42A5

2500

1.8

1/4

3,5

4.1

3.6

42A5

2500

2.7

1/3

3,5

4.1

4.8

42A7

2500

2.3

1/3

2,3,5

4.9

4.0

42A7

2500

3.4

1/2

2,3,5

5.0

5.7

42A7

2500

3.3

7/16

2,3,5

5.0

5.7

 FIGURE 3–

Setup of dip switches 7 and 8

Switches

Acceleration/Deceleration Time Range (seconds)

6

7

8

ACC pot fully CCW (factory setting) 

ACC pot fully CW

Off

Off

.1

.3

Off

On

.5

2.0

On

Off

3.5

12.0

On

On

4.0

15.0

1.  For armature speed of a geared motor, multiply the output speed at the driveshaft by the 

gear ratio.

2.  If the user desires to install their own armature fuse on the control output to protect the motor 

from continuous overloads, base fuse ratings on the motor rating in this column.

3.  Peak current available with TORQ pot in fully CW position (factory setting). This current exceeds 

the continuous rating of the motor and is for intermittent overload conditions only.

4.  Use this column for sizing a line fuse on the control input.

5.  The REG potentiometer must be turned fully CCW (off) for high-speed type 24ABEPM motor.

6.  Time for voltage across A1 and A2 to ramp up to 130 V when speed pot is turned from 0 to 100; 

or to ramp down to 0 V when it is turned from 100 to 0. The time for a motor to accelerate from 0 

to 2500 rpm or decelerate from 2500 to 0 rpm is dependent on motor size and loading conditions.