25
8.2 Time output management menu
This menu can be used to view all the time outputs, modify their status (Start/
Stop), configure the DHF distribution in Init mode and configure the “impulse”
and “D1D2” distribution.
This menu allows you also to configure the impulse output (Impuls 01) to
provide TBT 24VDC (1A) power supply.
To go to the SIGMA time output management
menu, validate the option in the technician
menu with the
key,
The following screen is displayed :
You can view the different options and
change the values using the
and
keys.
You can go through the different outputs by
validating using the
key.
The 3 outputs (Impulse 01, Afnor 02 and
DHF03) are not programmable with a time
zone differential.
The placing of a DHF output in “INIT” status is active for 4 hours before return
to START mode (The init mode display is alternating with the normal display
during this period).
This menu can be used to set the power of the DHF output with a choice of
25mW / 125mW (by default) / 500mW and assign the system address from 1
to 4 (2 by default).
Buzzer mode allows you to activate a buzzer on the secondary transmitters in
order to identify them.
For an “impulse” or “D1D2” output, the
key can be used to go to the configuration
menu.
Time outputs ok
Function setting õ
D1D2 minute:06s ú
START 00:00 ok
Afnor 02: START ú
ok
DHF 03 : INIT ú
125mW channel:2 ok
D1D2 minute:06s ú
START 00:00 ok
Содержание Sigma H
Страница 3: ...3 SIGMA H Installation and start up instructions ...
Страница 36: ...36 ...