Bob’s Space Racers® Inc. © 2017
3-1
Chapter 3: Maintenance Tip
3.1 Maintenance Introduction
3.1.1
Section 3.2 is the procedure to service the coil bed.
Please Note: If at any time, you require more assistance, please do not hesitate to call BSR’s tech support: 386-677-0761.
T
URN OFF GAME POWER WHEN PERFORMING THIS OPERATION
.
Please Note: Read all the instructions before performing any procedures.
3.2 Coil Bed Servicing
3.2.1
The coil bed is the assembly that houses the solenoids, score sensors and Whac-A-Mole
heads. This unit is built as an assembly to make servicing and repair easy. The entire unit removes
from the game as a sub-assembly in just a couple of minutes.
3.2.2
A quick fix for a sluggish shaft. BSR recommends to use an all-purpose Silicone Lubricant.
Warning!
Do not use graphite spray. It is conductive and you could short out the electrical wiring and or
the Printed Circuit Board (PCB).
3.3 Cleaning Mole Head Shafts
3.3.1
Turn off the Game power.
3.3.2
Remove the 2 bolts that attach the playfield to the top of the main cabinet.
3.3.3
Lift the playfield up and pull forward to remove it from the unit.