COMMISSIONING
General commissioning procedure
Clean the connection area (remove material residues and dirt).
Before commissioning, check that all screw and clamp connections are tight!
Check that all unused cable glands are properly sealed with dummy plugs or dummy connections.
Switch on the supply voltage. After start-up and after the self-test, the RFID status display is white.
Complete the specified initial tests in compliance with local regulations and laws.
Close the Wallbox terminal panel cover if it has been opened, see section
.
Install the housing cover, see section
Commissioning mode/Self-test
The Wallbox can be switched to commissioning mode to support the initial system test. A device self-
test is carried out (lock, contactor control, current measurement, etc.) and an error is displayed.
After a successful test without the vehicle connected, the contactor is switched for a limited time (~10
minutes) to enable the initial tests. Normal charging is not possible in commissioning mode.
The lock on the charging socket is activated to prevent a connection (Wallbox versions with a charging
socket only).
For safety reasons, switching on the Wallbox in commissioning mode via the supply voltage leads to an
error (white-red-red-red) in order to prevent unattended activation.
Activating commissioning mode
1. Set the DIP switch
DSW2.8
to
ON
.
2. Reset the Wallbox. To do this, press the
Service button
for
1 second
(signal tone).
Commissioning mode is now enabled and is indicated by the status LED being lit in orange.
3. It is now possible for approximately 10 minutes to contact with the measuring instrument using
standard test clips (for example Astaco® test clips from BEHA) and conduct the required safety
tests. After this time the contactor is disabled and the Wallbox switched off.
Deactivating commissioning mode
1. Set the DIP switch
DSW2.8
back to
OFF
.
2. Reset the Wallbox. To do this, press the
Service button
for
1 second
(signal tone) or switch the
supply voltage off and on again. The Wallbox starts up in normal operating mode and is ready for
operation.
44
Содержание MINI Wallbox Essential
Страница 1: ...MINI Wallbox Plus Installation instructions Freude am Fahren ...
Страница 2: ......
Страница 3: ...MINI Wallbox Plus Installation instructions 5 EN ...
Страница 4: ......
Страница 49: ...MISCELLANEOUS Dimensions Dimensions in millimetres EN 49 ...
Страница 56: ...PRODUCT INFORMATION PAGE This telecommunications equipment complies with the NTC requirement 56 ...
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ...Mehr über BMW www bmw de www bmw com Freude am Fahren Doc 108154 Mat 108154 IA MINI Wallbox Plus 1 0 ...