…when it comes to quality!
BMR GmbH
13
7.5 Control via LED Front Board
Mains Switch
After the Power-button is switched "ON", the Frequency Converter starts an automatically
self-test for about 8 seconds. During this time all displays flashes a short time one after
another. After this automatical check the converter is ready for operation.
In case of defect the corresponding display flashes.
Spindle "Start"
After pressing the „START“-button the spindle starts to come up to the rotational speed
adjusted by the rotary knob (11). The acceleration time is adjusted to 10.000 rps on factory
default.
On request other acceleration times are possible.
Spindle "Stop"
After pressing the "STOP"-button the spindle will be electronically decelerated and stopped to
standstill. The deceleration time corresponds to the adjusted acceleration time.
It’s only possible to slow down the spindle with the „STOP“-button if the remote control is
not
„ON“.
By pressing power switch „OFF“ there is no electronic slow down, but the spindle runs out by
itself.
Digital Display of Rotational Speed
The digital display of rotational speed indicates the adjusted rotational speed by n x 1000
LED Load Display
Display of Rotational Speed
RPM Poti
START Button
STOP Button
Mains Switch
LED Display for
Converter Status