MANUAL
Power Packet
in a small Size:
Handheld High Frequency Converter SFU 0150
BMR GmbH 2008
Страница 1: ...MANUAL Power Packet in a small Size Handheld High Frequency Converter SFU 0150 BMR GmbH 2008 ...
Страница 2: ...Please read this manual carefully before the first use Version 06 April 2009 Congratulation for purchasing a BMR GmbH product We thank you for the decision for choosing a BMR GmbH device and wish you much success ...
Страница 3: ...ins 5 4 Mains Switch and Fuse 6 Functions Setup Operation 6 1 Front Panel 6 2 Setup of Rotational Speed 6 3 Starting and Stopping the Frequency Converter 6 4 Setup of Direction of Rotation 6 5 Operation 7 Safety Functions 8 EMC Electro Magnetic Compatibility 9 Dimensions SFU0150 10 EG Declaration of Conformity 11 General Hints 12 Warranty 4 5 6 7 8 9 9 9 9 10 10 11 11 12 12 13 13 14 15 16 17 ...
Страница 4: ...the fixed 50 Hz network into a 3 phase network with variable frequency and voltage This greatly reduces the start up problems and the high starting currents that are unavoidable when high capacity three phase A C motors are connected to a fixed network The motor is controlled according to a special characteristic curve until its rated speed has increased or it has been stopped The SFU 0150 series ...
Страница 5: ...ntrol Mode The highest efficiency of motors at both low and high frequencies is made possible Highest level of operational safety All operating states such as acceleration operation at rated speed and deceleration are monitored and critical situations are intercepted and brought under control automatically Display of Rotational Speed current load condition and converter status message on three 7 s...
Страница 6: ...On 3 x 7 segment LED On 3 x 7 segment LED As bar graph on 1st 7 segment LED 200 x 120 x 105 W x H x D mm App 2 5kg IP20 ambient temperature 10 C 40 C max 80 humidity content Mains connection Mains Switch Fuse Output Power Spindle Connection Output voltage Output current Output frequency Control input Display of rotational speed Display of status Display of load condition Dimensions Weight Protecti...
Страница 7: ... movement of the motor Safety regulations that are valid for the country where the device is used must be applied when repair or maintenance work is carried out on the device Maintaining EMC electro magnetic compatibility limits is the responsibility of the manufacturer of the machine or device The inputs on this device are fitted with filters to increase the interference immunity and to reduce em...
Страница 8: ... 8 5 Connections Plugs and Pinouts Spindle Connector Remote Control Connector ATTENTION Please do not connect any external voltages to the remote control pins On Off Switch in combination with a resettable fuse ...
Страница 9: ...olated contact ON OFF ON OFF Variable rotational Speed Remote Control by a external PLC 3 pin butterfly mains connector The mains switch is realized as a combination between a push push button mains switch and a thermo protection fuse for 1A Exeeding the rated current will trigger the thermo fuse to switch in the OFF Position Pin 1 R Pin 2 S 3 Phase for Spindle Pin 3 T 5 2 Spindle Connector 3 Pin ...
Страница 10: ...ties for Operation Manually with the buttons on the front panel Operation with footswitch ON OFF BMR Vario foot controler ON variable rot speed OFF Galvanically isolated contact remote control ATTENTION Please do not connect any external voltages to the remote control pins ...
Страница 11: ...ional speed can be increased or decreased depending on the pressure applied to the foot controller For example for the max rpm the foot pedal has to be pushed completly down 6 3 Starting and Stopping the Frequency Converter Because of multiple requirements the frequency converter SFU0150 can be started and stopped in several ways Manually with the help of the push buttons at the front panel With a...
Страница 12: ...he push buttons are left un pressed for more than 10 sec it is switched back to operating mode If the converter is started and the spindle is spinning the speed of rotation is displayed at the right LED digits The horizontal bars of the left digit serves as display of current load condition Some display examples The converter is set to 10 thousand rpm each idle running or load 30 load 30 59 load 6...
Страница 13: ...ected components motor spindle length and type of cables wiring etc Under certain conditions the use of additional filters can be necessary to maintain the current laws The ground and shield connections of all devices used in conjunction with the frequency converter should be as short as possible and have as large cross section as possible Control devices used with the frequency converter PLC CNC ...
Страница 14: ... 0150 14 9 Dimensions SFU 0150 Subject to technical changes Edition April 12 2008 ATTENTION Old electric and electronic devices must not be placed into the domestic waste but have to be disposed separately ...
Страница 15: ...re applied EN 61800 3 C3 standards which are also complied with VDE 0839 Teil 6 4 IEC 61000 6 4 VDE 0160 Teil 100 IEC 61800 3 VDE 0847 Teil 4 8 IEC 61000 4 8 VDE 0847 Teil 5 5 IEC 61000 4 5 VDE 0875 Teil 11 Bbl 1 IEC CISPR 11 CISPR TR 28 VDE 0847 Teil 4 6 IEC 61000 4 6 VDE 0847 Teil 4 2 A1 IEC 61000 4 2 A1 VDE 0847 Teil 4 11 IEC 61000 4 11 VDE 0847 Teil 4 3 IEC 61000 4 3 A1 VDE 0839 Teil 6 2 IEC 6...
Страница 16: ...enance on the converter and the relating accessories must be carried out by skilled and instructed persons in the OFF state only To ensure this the mains plug should be pulled out In doing this both the terms of regulations for preventing accidents and the general and national rules for mounting and safety have to be applied Our high frequency converters are highly valuable precison devices Please...
Страница 17: ...g or replacing of the defective parts We refuse claims of responsibility or warranty for direct or indirect consequential damages caused by faults of our products Changes in construction may be carried out without any message or notification Our common terms of business conditions apply Subject to technical changes BMR GmbH is a dynamic and flexible company We take into account specific requiremen...
Страница 18: ...y in the quality and test department the devices are tested and set up according to the customers requirements We have established short ways between the departments in order to guarantee a constant level of high quality and to be able to realize changes fast and in a flexible way By keeping the manufacturing processes within our company we have gained years of knowledge and experience offering th...
Страница 19: ...stic appliances Acoustic test units Motor controls Accumulator charger Time controls for example grease controls used in automotive applications Development of oem controls Manufacturing of electronic devices using wire through and surface mount technique We also work as an extended workbench for well known companies Our present product profile ...
Страница 20: ... and requirements for our products This concept is valued by our customers and becomes evident in our steadily growing presence in the market at home and abroad If you are interested in our products and accessories contact us or visit us on our website www bmr gmbh de BMR GmbH Unterreichenbacher Strasse 1 90455 Nuernberg Katzwang Germany Phone 49 0 9122 63148 0 Fax 49 0 9122 63148 29 e mail info b...