11
MOUNTING
The BC300 External Shunt has two mounting terminals. Using these
terminals the BC300 External Shunt is wired in series with the negative
terminal of the battery being monitored and the negative battery loads. The
‘+’ flying lead provides a connection to the positive terminal of the battery
to power the BC300 External Shunt. This lead is also used to measure the
battery temperature and voltage and must be directly connected to the
positive terminal of the battery.
Please ensure that all loads connected to the battery are disconnected or
turned off before beginning the installation procedure below to avoid sparks
being generated during this process.