background image

F2 Full Face Mask User Manual V2.1

 

6

 / 

14

 

E

n

g

lis

h

 

Fitting the Mask 

Use  a  standard  conical  connector  if  pressure  readings  and  /  or 
supplemental oxygen are required. 

 

 

 

Pass the upper straps 
of the headgear 
through the installation 
hole of the mask as 
shown in the figure 
and secure it, repeat 
the process with the 
lower straps. 

Place the mask on the 
face and extend the 
headgear to the back 
of the head / Please 
confirm that the label 
on the back of the 
headgear faces 
outward when the 
headgear is worn. 

Bring the lower-half 
straps beneath the 
ear and encircle the 
face and then insert it 
into the fixed hook on 
the lower-half part of 
the mask frame. 

 

 

 

Extend the upper-half 
straps of the headgear 
as shown in the above 
figure until the mask is 
fixed properly. 

Repeat the process for 
the lower-half 
headgear as shown in 
the above figure until 
the mask is fixed 
properly. 

Open the device for 
the air supply. Attach 
the respiratory hose 
with the connector on 
the base of the mask. 
Adjust the position of 
the mask to confirm a 
tight seal. 

 

Содержание BMC-FM2

Страница 1: ...English F2 Full Face Mask User Manual 0123...

Страница 2: ...ask 2 Components of the F2 Full Face Mask 4 Getting the Right Cushion Size 5 Fitting the Mask 6 Disassembling the Mask 7 Cleaning the Mask at Home 8 Reprocessing the Mask between Patients 9 Reassembli...

Страница 3: ...r mask Intended Use The F2 Full Face Mask channels airflow non invasively to a patient from a positive airway pressure device such as a continuous positive airway pressure CPAP or bi level system The...

Страница 4: ...s warning applies to most models of CPAP systems At low CPAP pressures the flow through the exhaled port may be inadequate to clear all exhaled gas from the tube Some rebreathing may occur To minimize...

Страница 5: ...generator If it is used beyond technical specifications or used with incompatible devices the seal and comfort of the mask may not be effective optimum therapy may not be achieved and leak or variati...

Страница 6: ...F2 Full Face Mask User Manual V2 1 4 14 English Components of the F2 Full Face Mask Components of the F2 Full Face Mask Cushion Forehead pad Frame assembly Headgear Elbow assembly Elbow Valve Swivel...

Страница 7: ...lowing drawing describes the different features of face and the length of the face H you need to measure The masks are available in three different sizes Choose the appropriate size according to the t...

Страница 8: ...that the label on the back of the headgear faces outward when the headgear is worn Bring the lower half straps beneath the ear and encircle the face and then insert it into the fixed hook on the lower...

Страница 9: ...ly cannot be disintegrated 3 The valve cannot be dissembled or damage may be incurred and the re installation will become more difficult 1 2 3 Undo and remove the upper half headgear straps out of the...

Страница 10: ...g any part of the system or tubing to direct sunlight or heat may cause deterioration If any visible deterioration of a component is apparent cracking crazing tears etc the component should be discard...

Страница 11: ...and disinfection instructions are available from the BMC website www bmc medical com If you do not have internet access please contact your BMC representative Reassembling the Mask 1 2 3 Install the...

Страница 12: ...sure the headgear is not over tightened Mask size is wrong Consult your clinician Mask leaks around the face The cushion is misplaced on the cushion frame Check insertion of the cushion and reinsert c...

Страница 13: ...sizes but is less than 218 mL Therapy Pressure 3 to 40 cmH2O Resistance Drop in Pressure measured average for 3 sizes at 50 L min 0 15 cmH2O at 100 L min 0 5 cmH2O Inspiratory and Expiratory Resistanc...

Страница 14: ...0 dBA with uncertainty 3 dBA Environmental Conditions Operating temperature 5 C to 40 C 41 F to 104 F Operating humidity 0 93 relative humidity non condensing Storage and transport 20 C to 55 C 4 F to...

Страница 15: ...nts Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device Lot number Catalog number Not made with natural rubber...

Страница 16: ...To exercise the rights under this warranty contact the local authorized dealers The expected service life of F2 Full Face Mask is one year MANUFACTURER BMC MEDICAL CO LTD Room 110 Tower A Fengyu Buil...