background image

1

Infrared

 

receiver

Installation

 

instructions

English

Type

IC

56

Infrared

 

Transmission

For

 

Touch

 

Probes

For

 

Tool

 

Setting

 

Probes

Содержание IC56

Страница 1: ...1 Infrared receiver Installation instructions English Type IC56 Infrared Transmission For Touch Probes For Tool Setting Probes ...

Страница 2: ...ions are subject to damages All rights reserved The language version of the manufacturer DE EN is decisive for the technical content Subject to technical change without notice Original operating instructions 2007 2018 by Blum Novotest GmbH All brands stated in this document are the property of the respective brand owners Article number of this documentation 180191_EN ...

Страница 3: ...lay elements 6 2 3 Dimensions 7 2 4 Technical data 7 2 5 Area of work 8 2 6 Complete system 9 2 7 System coding 9 3 Mounting and commissioning 10 3 1 Mounting position 10 3 2 Mounting variants 12 4 Electrical connection 15 5 Maintenance 15 6 Order numbers 16 7 Shipping instructions storage 17 8 EC Declaration of Incorporation 18 9 Service 19 ...

Страница 4: ...TION signifies a danger which may cause injuries if it is not avoided NOTICE signifies measures to avoid material damages Advice for secondary literature Additional advice Don t use compressed air for this step The CE label confirms that the product as described complies with the product spe cific European regulations Green Red Blue Orange LED shines LED flashes Md tightening torque ...

Страница 5: ... A3 Data transfer to the NC control via IF59 A2 interface NOTICE Risk of collision Measuring systems TC series Z Nano IR type A1 cannot be operated with the infrared receiver Fig 2 1 9 0 1 2 3 4 ON 1 2 3 4 5 6 7 8 9 0 IF59 1 7 2 9 6 8 4e 4d 4a 4c 4b 1 Transmission diodes 2 Receiver diode 4a LED Mode 4b LED Battery 4c LED Status 4d LED Receive IR 4e LED transmit IR flash On Off 6 Cable 7 for mounti...

Страница 6: ...UO Reserved Battery 4b Battery o k Battery low Status 4c Initial position Probe deflected collision Receive IR 4d off No reception Interference incorrect reception Reception o k Wrong system Transmit IR Flash On Off 4e Send command Send flash The LED s are explained on enclosed label Please fix label clearly visible on the machine ...

Страница 7: ...9 5 3 2 Ø6 Ø3 3 M4 a a Wall bushing Ø 20 mm Ø 38 mm Protection class IP68 Power supply 12 V DC 100 mA via IF59 Air nozzle Integrated max 6 bar 0 6 MPa Signal transmission Infrared Min bending radius cable 60 mm application flexible Max cable length 50 m Mass 700 g Storage temperature 20 C 70 C Operating temperature 5 C 50 C ...

Страница 8: ...IR IC56 30 20 10 40 50 60 70 30 20 10 40 50 60 70 1m 2m 3m 4m 5m 6m 6m 5m 4m 3m 2m 1m 30 20 10 40 50 60 70 30 20 10 40 50 60 70 Area of work 100 Activation high The adjustment of the transmitter power on the probe 50 reduces the working range The adjustment to reduced transmitter power interface IF59 Dip Switch 10 ON re duces the activation range by the half Probe with robust design for lathes app...

Страница 9: ...For customer specific codes the white label can be marked NOTICE Risk of collision due to lack of labelling possible In order to avoid mistakes the measuring system and the machine must be coded Please always use the transparent label to protect Fig 2 6 IC56 battery o k battery low www blum novotest com IC56 TC IC56 DUO send flash initial position probe deflected Probe 2 Probe 1 Mode standby mode ...

Страница 10: ...the sharp edges on the cable bushing and mount edge protection NOTICE Damage by improper installation of cables and hoses When mounting cables and hoses please provide sufficient strain relief Please note the minimum binding radius of cables and hoses NOTICE Damages caused by improper installation dismounting Please only use original replacement parts as well as the provided special tools Consider...

Страница 11: ...Mounting and commissioning by Blum Novotest 11 V2A 04 2018 Fig 3 1 142678 ...

Страница 12: ...2A 04 2018 12 by Blum Novotest 3 2 Mounting variants Horizontal facing cable NOTICE Pollution of the system Mount seal insert and O Ring at horizontal facing cable Fig 3 2 Vertical facing cable Fig 3 3 9 10 9 Seal insert 10 O ring ...

Страница 13: ... 13 V2A 04 2018 Fig 3 4 9 149358 142680 10 M3 M4 M6 8 8 Universal holder 9 Seal insert 10 O ring Tightening torque DIN EN ISO 4762 DIN912 M3x10 M4x10 M6x12 Md 1 3 Nm max Md 3 0 Nm max Md 10 5 Nm max Drilling template data sheet scope of delivery ...

Страница 14: ... 3 6 Front Kit Adapter 15 30 Fig 3 7 Light protection shield 11 60 27 19 8 5 22 16 M6 Ø5 2 11 Clamping screw Md 1 5 Nm 142684 15 142677 30 15 30 142676 Please find detailed designs and dimensions in the data sheets 142678 360 Please find detailed designs and dimensions in the data sheets ...

Страница 15: ...Electrical connection by Blum Novotest 15 V2A 04 2018 4 Electrical connection 5 Maintenance The receiver needs minimum maintenance only Keep the viewing glass clean Installation instructions IF59 ...

Страница 16: ...arts and accessories by Blum Novotest only Infrared receiver IC56 Cable length L 10 m PUR Cable length L 20 m PUR 8 wires 142636 142639 Front Kit 142676 Adapter 15 Adapter 30 142684 142677 Light protection shield 142678 Heavy Duty Kit Protection spring 1 m incl screwing 142680 ...

Страница 17: ...The measuring system should be packed shock and pollution protected Service order Please complete this repair order answering all questions in detail and attach it to the system It will be more cost effective for both parties if we have all the information and will ensure a prompt repair service Blum Novotest GmbH Kaufstr 14 88287 Gruenkraut Germany Tel 49 751 6008 0 Fax 49 751 6008 156 Company De...

Страница 18: ...are installed are in accordance with the EC regulations 2006 42 EC The relevant technical information is compiled acc to annex VII part B and where appropriate we will send the information concerning the components to the different countries The indus trial property rights of Blum Novotest GmbH will remain unaffected Component name IC56 Infrared receiver Safety requirements 2006 42 EC Annex I 1 5 ...

Страница 19: ...orldwide Blum Novotest GmbH Kaufstr 14 88287 Grünkraut Germany Tel 49 751 6008 0 Fax 49 751 6008 156 www blum novotest com Vertrieb Sales Service sales blum novotest com service blum novotest com Hotline Vertrieb Sales Service Tel 49 751 6008 200 Tel 49 751 6008 202 ...

Страница 20: ......

Отзывы: