MPPT Solar Controller

Characteristics

MPPT series controller is  suitable for the street light

system. The controller features a smart tracking algorithm

inside that maximizes the energy from the solar PV

module(s) and charge the battery. At the same time, the

low voltage disconnect function (LVD) will prevent the

battery from over discharging.

The controller charging process has been optimized for

long battery life and improved system performance. The

comprehensive self-diagnostics and electronic protection

functions can prevent damage from installation mistakes

or system faults.

Peak conversion efficiency of 97 %, high Tracking

efficiency of 99%.

Very fast sweeping of the entire I-V curve, several

seconds tracking speed.

Widely used, automatic recognize day/night.

Timer function with 1-15 hours option for street light.

Unique dual timer function, enhance the flexibility of

street light system.

Sealed, Gel and Flooded battery option.

Adopting temperature compensation and correcting the

charging and discharging parameters automatically,

improving the battery lifetime.

Electronic protection: over charging, over discharging,

overload, short circuit.

Reverse protection: any combination of solar module

and battery, without causing damage to any component.

RJ45 interface with remote meter MT-5, convenient to

check operating parameters of controllers. ( MT-5 is

optional)

1

PLURIGÁS SOLAR ENERGIAS Lda. - End: Urb. António Aleixo -1 , 4820-358 Fafe, Portugal

Tel : +351 253700060 - Fax : +351 253700065 – Site: www.plugassolar.pt – Email: [email protected]

Содержание 10 A

Страница 1: ...ing of the entire I V curve several seconds tracking speed Widely used automatic recognize day night Timer function with 1 15 hours option for street light Unique dual timer function enhance the flexibility of street light system Sealed Gel and Flooded battery option Adopting temperature compensation and correcting the charging and discharging parameters automatically improving the battery lifetim...

Страница 2: ...5 5V 31 0 V High Volt Disconnect 16 0V 32 0 V Self consumption 30 mA Discharge Circuit Voltage Drop 170 mV Charging Mode Modo MPPT Temperature Compensation Coefficient 30mV 12V 25 NTTV Night Time Threshold Voltage 5V 10V DTTV Day Time Threshold Voltage 6V 12V Terminal 4 mm 10 mm 25 mm 25 mm Ambient temperature range 35ºC 55ºC Humidity range 10 90 NC Communication TTL232 8 pin RJ45 Dimension mm 156...

Страница 3: ... indicator will be on when set timer1 timer2 and battery type 5 LED Digital Display Display the load work mode and status 6 Setting Button in manual mode used for load ON OFF Set load work mode and select battery type 7 Solar Module Terminals Connect solar modules 8 Battery Terminals Connect batteries 9 Load Terminals Connect loads 10 RJ45 Communication Interface Communicate with remote meter MT 5...

Страница 4: ...g instructions refer to a singular battery but it is implied that the battery connection can be made to either one battery or a group of batteries in a battery bank Select the system cables according to 3A mm2 current density 2 1 MOUNTING Step 1 Choose Mounting Location Locate The Controller on a vertical surface protected from direct sun high temperature and water Step 2 Check for Clearance Place...

Страница 5: ... output as shown in figure 3 3 The load terminals may exist voltage connect carefully to avoid short circuit An in line fuse holder should be wired in series in the load positive or negative wire as shown Do not insert a fuse at this time Confirm the connection correct and then turn on the power If wiring the load connection to a load distribution panel each load circuit should be fused separately...

Страница 6: ...he Controller Power Out of the Tracer 2 Volts In Amps In Volts Out Amps Out Assuming 100 efficiency Actually the losses in wiring and conversion exist If the solar module s Vmp is greater than the battery voltage it follows that the battery current must be proportionally greater than the solar input current so that input and output power are balanced The greater the difference between the maximum ...

Страница 7: ...rge current the controller will no longer be able to maintain the battery at the Float set point Should the battery voltage remains below the boost reconnect charging voltage the controller will exit Float stage and return to Bulk charging Equalize WARNING Risk of explosion Equalizing flooded battery can produce explosive gases so well ventilation of battery box is necessary NOTE Equipment damage ...

Страница 8: ...voltage and turn off the load after 10 minutes delay 3 2 2 Light ON Timer 1 15h on When solar module voltage goes below the point of NTTV Night Time Threshold Voltage at sunset the solar controller will recognize the starting voltage and turn on the load after 10 minutes delay for several hours 3 2 3 Test Mode It is used to test the system and the same as Dusk to Dawn But there is no 10 minutes de...

Страница 9: ...sunset 5 Load will be on for 15h after 10 min delay since sunset 6 Test Mode 7 ON OFF Mode LED Nº TIMER 2 0 Sem atraso a carga é ligada após anoitecer 1 Load will be on for 1 hour before sunrise 2 Load will be on for 2 hour before sunrise 3 Load will be on for 3 hour before sunrise 4 Load will be on for 4 hour before sunrise 5 Load will be on for 5 hour before sunrise 6 Load will be on for 6 hour ...

Страница 10: ...it occurs the controller will automatically resume to work after 10s when a second short circuit occurs press the button the controller will resume to work after 3s Maintenance The following inspections and maintenance tasks are recommended at least two times per year for best controller performance Check that the controller is securely mounted in a clean and dry environment Check that the air flo...