FAULT DETECTION
Please contact local service center to do the maintenance.
CODE
CAUSE OF FAILURE
TREATMENT
1
Can not
close the
lid
Inner cover does not well
instelled
Instell the inner cover in right
position
2
Can not
open the
lid
Lid open button failure
Repair in after-sales maintance
Inner cover does not well
instelled
Instell the inner cover in right
position
3
Lid
leakage
Inner cover does not well
instelled
Instell the inner cover in right
position
Food residue in
sealing ring
Clean the sealing ring
Sealing ring demaged
Repair in after-sales maintance
4
No LED
display
after
connect
power
Poor connect in power
socket
Re-check the power socket
The fuse has blown out
Repair in after-sales maintance
5
E0
System failure, NO coil
plate and drive circuit,
circuit malfunction
Repair in after-sales maintance
6
E1
No inner pot inside
Put the inner pot back inside
7
E2
IGBT NTC FAILURE
Repair in after-sales maintance
8
E3
high voltage warming
Unstable voltage, wait for the stable
voltage and use
9
E4
low voltage warming
Unstable voltage, wait for the stable
voltage and use
10
E5
Top sensor open circuit
Repair in after-sales maintance
11
E6
Top sensor short circuit
Repair in after-sales maintance