Features of your Blueprint Digital Cycle Timer
120V, BDCT-1
• Precisely controls a 120V device on an adjustable on/off cycle
• Integrated photocell allows day, night or 24-hour operation
• Digital clock with lithium battery backup
• Wall mountable
• 3-year warranty
Specifications
Input Voltage: 120V
Maximum Amperage: 14.5A @ 120V
Timer Settings: Day ON/OFF, Night ON/OFF
On/Off Setting Range: 1 second to 168 hours
Dimensions: 3” x 6” x 3.5”
Equipment Power
Connection
Photocell
Wall Mount Access
LCD Screen
Menu Button
LED Indicator
Enter Button
Up Button
Down Button
Installation
1. Connect the unit to a 120V power source.
2. If desired, mount the unit to the wall or alternate support using
the mounting tab.
3. Program desired settings.
4. Connect the device to be controlled.
Ensure the device being connected
to the Controller has the proper voltage and
will not exceed the maximum amperage
rating of the unit.
Do not expose the unit to water.
Factory Settings
• Day On Time: 1 Minute
• Day Off Time: 1 Hour
• Night On Time: 10 Seconds
• Night Off Time: 2 Hours
• Select Timer Mode: Day
• Photocell Function: Active
• Power Loss Mode: Continue
Restoring Factory Settings
Factory settings can be reinstated at any time by pressing and
holding the MENU and UP arrow buttons for 3 seconds, then
pressing ENTER.
LCD Screen
If the timer is active, the timer will be counting down the
remaining time.
Selecting Timer Settings
Day On Time:
To set the amount of time the output will be
cycled on when the photocell detects light, press the MENU but-
ton to display the first menu item. Use the UP and DOWN arrow
buttons to scroll through and find “Set Day On Time” on the LCD
screen. To change the settings, press the ENTER button. The
current hour setting will be highlighted to indicate the setting can
be changed. Enter the hour setting using the UP and DOWN ar-
row buttons and press the ENTER button to move to the minute
setting. Enter the minute setting using the UP and DOWN arrow
buttons and press the ENTER button to move to the seconds
setting. Enter the seconds setting using the UP and DOWN
arrow buttons and press the ENTER button to accept the new
settings and store them into memory.
Caution
Warning
Photocell Status
Output Status
Time Remaining
rev:112013