Thank you for choosing to grow with Blueprint
Controllers! Your satisfaction and success are
important to us. For best results, carefully read
the following instructions before using your
Blueprint Compact Digital CO
2
Controller.
Features of your Blueprint Compact Digital
CO
2
Controller, BCDCC-1
• Precisely controls CO
2
generating devices
• Remote sensor on a 16’ cable accurately monitors CO
2
levels
• Integrated photocell allows day, night or 24-hour CO
2
control
• Stores minimum and maximum CO
2
values
• Wall mountable
• 3-year warranty
Specifications
Input Voltage: 120V
Maximum Amperage: 14.5A @ 120V
CO
2
Sensor Type: NDIR (Nondispersive Infrared)
CO
2
Control Range: 350-2500 ppm
CO
2
Deadband: 50-250 ppm
Dimensions: 3” x 6” x 3.5”
Menu Button
LED Indicator
LED Indicator
Enter Button
Up Button
Down Button
Equipment Power
Connection
CO
2
Sensor
Hanger
LCD Screen
Wall Mount Access
Photocell
Installation
1. Connect the unit to a 120V power source.
2. If desired, mount the unit to the wall or alternate support using
the mounting tab.
3. Program desired settings.
4. Position remote sensor in best location to accurately gauge CO
2
levels for proper unit functioning.
5. Connect the device to be controlled.
Ensure the device being connected to the
Controller has the proper voltage and will not
exceed the maximum amperage rating
of he unit.
Do not expose the unit to water.
Factory Settings
• CO
2
Set-point: 1250 ppm
• Photocell mode: Day
• CO
2
Sensor: 380 ppm
• CO
2
Deadband: 50 ppm
• CO
2
Mode: Increase
Restoring Factory Settings
Factory settings can be reinstated at any time by pressing and
holding the MENU and UP arrow buttons for 3 seconds, then
pressing ENTER.
LCD Screen
Selecting CO
2
Settings
CO
2
Set-point:
To set the CO
2
level that will be maintained by
the controller, press the MENU button to display the first menu
item. Use the UP and DOWN arrow buttons to scroll through and
find “Set CO
2
Setpoint” on the LCD screen. To change the setting,
press the ENTER button. The current setting will be highlighted to
indicate the setting can be changed. Use the UP and DOWN arrow
buttons to change the setting. Press the ENTER button a second
time to accept the new setting and store it in memory.
Caution
Warning
Photocell Mode
CO
2
Level
Current Mode
rev:112013