Thank you for choosing to grow with Blueprint 

Controllers! Your satisfaction and success are 

important to us. For best results, carefully read 

the following instructions before using your 

Blueprint Compact Digital CO

2

 Controller.

Features of your Blueprint Compact Digital 

CO

2

 Controller, BCDCC-1

• Precisely controls CO

2

 generating devices

• Remote sensor on a 16’ cable accurately monitors CO

2

 levels

• Integrated photocell allows day, night or 24-hour CO

2

 control

• Stores minimum and maximum CO

2

 values

• Wall mountable

• 3-year warranty

Specifications

Input Voltage: 120V

Maximum Amperage: 14.5A @ 120V

CO

2

 Sensor Type: NDIR (Nondispersive Infrared)

CO

2

 Control Range: 350-2500 ppm

CO

2

 Deadband: 50-250 ppm

Dimensions: 3” x 6” x 3.5”

Menu Button

LED Indicator 

LED Indicator 

Enter Button

Up Button
Down Button

Equipment Power 

Connection

CO

2

 Sensor

Hanger

LCD Screen

Wall Mount Access

Photocell

Installation

1. Connect the unit to a 120V power source.

2. If desired, mount the unit to the wall or alternate support using  

  the mounting tab.

3. Program desired settings.

4. Position remote sensor in best location to accurately gauge CO

2

  

  levels for proper unit functioning.

5. Connect the device to be controlled. 

  

 

 

   

 

Ensure the device being connected to the  

   

 

Controller has the proper voltage and will not  

   

 

exceed the maximum amperage rating    

   

 

of he unit.

    

    

Do not expose the unit to water.

Factory Settings

•  CO

2

 Set-point: 1250 ppm

•  Photocell mode: Day

•  CO

2

 Sensor: 380 ppm

•  CO

2

 Deadband: 50 ppm

•  CO

2

 Mode: Increase

Restoring Factory Settings

Factory settings can be reinstated at any time by pressing and 

holding the MENU and UP arrow buttons for 3 seconds, then 

pressing ENTER.

LCD Screen

Selecting CO

2

 Settings

CO

2

 Set-point:

  To set the CO

2

 level that will be maintained by 

the controller, press the MENU button to display the first menu 

item. Use the UP and DOWN arrow buttons to scroll through and 

find “Set CO

2

 Setpoint” on the LCD screen. To change the setting, 

press the ENTER button. The current setting will be highlighted to 

indicate the setting can be changed. Use the UP and DOWN arrow 

buttons to change the setting. Press the ENTER button a second 

time to accept the new setting and store it in memory.

Caution

Warning

Photocell Mode

CO

2

 Level

Current Mode

rev:112013