28
www.BlueBoxOptics.com V2.4
niji
Figure 18: RS232 Communication Interface
Note
: If a command string is sent to the equipment via serial connection, the software
will not indicate the change in state.
8.1
Communication
When connecting the equipment via a serial connection, serial connection software
such as Hyper terminal or Termite are recommended. The serial port should be
configured as follows:
Port
<select COM>
Baud rate
115200
Data bits
8
Stop Bit
1
Parity
None
Flow control RTS/CTS
Forward
None
Transmitted
CR and LF
Figure 19: Port Setup
8.2
Channel Level Command String
The serial command string is split into three parts. These are the command identifier,
the channel and the channel level. The command string is constructed as follows:
d,1,0
<Command>, <Channel Select (1-7)>, <Channel Level (0-100)>
8.3
Channel Level Set: Example
Should we wish to set Channel 2 to 60%. The command string would be constructed
as follows:
d,2,60
Содержание niji
Страница 1: ...User Manual niji...
Страница 14: ...13 www BlueBoxOptics com V2 4 niji...
Страница 18: ...17 www BlueBoxOptics com V2 4 niji Figure 8 TTL Mode Active...