BLUEBOX Gen.2 HFM
Page 20 of 37
Byte
Value
Description
Notes
8
0x..
Flags. Single bits are dedicated to disable (0
value) or enable (1 value) functions:
•
Bit 7: automatic buzzer management
•
Bit 6: automatic output 1 management
•
Bit 5 … bit 1: not used
•
Bit 0: to disable ‘continuous’ mode
3.12
Default parameters programming
This command is used to set the default values of the communication and
operating parameters of the
BLUEBOX
.
Byte
Value
Description
Notes
1
0x31
Command code
The answer to this command is given in short form through the ‘Reply Ack’ /
‘Reply Nak’ flags (this command don’t ‘produce’ data).
Note: after the command execution, the
BLUEBOX
resets itself to apply the
new parameters.
3.13
Digital Output Activation
This command is used to excite each individual output and to set also the
duration in case of impulsive use.
Byte
Value
Description
Notes
1
0x37
Command code
2
0x..
Output to activate:
•
0x01 -> Output 1
•
0x02 -> Output 2
3
0x..
Activation time:
•
0x01 … 0x63 (1 ... 99 seconds -> in
case of ‘impulsive’ output activation
•
0x81 -> ‘Continuous’ activation
•
0x80 -> Deactivation
The answer to this command is given in short form through the ‘Reply Ack’ /
‘Reply Nak’ flags (this command don’t ‘produce’ data).
3.14
Status Reading
The
BLUEBOX
will answer to this command with a series of information about
the current status and particularly about the digital inputs status.
Byte
Value
Description
Notes