BLUEBOX Gen.2 HFM
Page 19 of 37
Byte
Value
Description
Notes
6
0x03
Don’t care value
0x03 suggested value
7
0x..
Filter time:
•
Decimal 0 … 99 for time in seconds
(0 … 99 seconds)
•
Decimal 100 … 199 for time in minutes
(0 … 99 minutes)
8
0x..
Flags: single bits are dedicated to disable
(0 value) or enable (1 value) functions:
•
Bit 7: automatic buzzer management
•
Bit 6: automatic output 1 management
•
Bit 5 … bit 1: not used
•
Bit 0: to disable ‘continuous’ mode
The answer to this command is given in short form through the ‘Reply Ack’ /
‘Reply Nak’ flags (this command don’t ‘produce’ data).
Note: after the command execution, the
BLUEBOX
resets itself to apply the
new parameters.
3.11
Operating Parameters Reading
This command is used to get the values of the operating parameters of the
BLUEBOX
.
Byte
Value
Description
Notes
1
0x2A
Command code
If command is not successfully executed, the answer is given in short form
through the ‘Reply Ack’ / ‘Reply Nak’ flags; otherwise, the
BLUEBOX
answers:
Byte
Value
Description
Notes
1
0x2A
Command code
2
0x..
Don’t care value
3
0x..
Don’t care value
4
0x..
Don’t care value
5
0x..
Don’t care value
6
0x..
Don’t care value
7
0x..
Filter time:
•
Decimal 0 … 99 for time in seconds (0 …
99 seconds)
•
Decimal 100 … 199 for time in minutes
(0 … 99 minutes)