BLUEBOX Gen.2 HFM
Page 18 of 37
Byte
Value
Description
Notes
1
0x3C
Command code
2
0x03
Command code
If command is not successfully executed, the answer is given in short form
through the ‘Reply Ack’ / ‘Reply Nak’ flags; otherwise, the
BLUEBOX
answers:
Byte
Value
Description
Notes
1
0x3C
Command code
2
0x..
Address:
Decimal 1 … 126
3
0x..
Buffers length:
•
0x00 -> 8 bytes
•
0x01 -> 12 bytes
•
0x02 -> 16 bytes
•
0x03 -> 20 bytes
•
0x04 -> 32 bytes
•
0x05 -> 64 bytes
4
0x..
Don’t care
5
0x..
Don’t care
6
0x..
Don’t care
7
0x..
Don’t care
8
0x..
Don’t care
3.10
Operating Parameters Programming
This command is used to set the operating parameters of the
BLUEBOX
that
are: hold time (00 ... 99 seconds), filter time (0 ... 99 seconds / 0 ... 99
minutes), flag for ‘automatic’ buzzer management (disabled, enabled), flag for
‘automatic’ output 1 management (disabled, enabled) and flag for ‘continuous’
mode (disabled, enabled).
Byte
Value
Description
Notes
1
0x2F
Command code
2
0xFF
Don’t care value
0xFF suggested value
3
0x48
Don’t care value
0x48 suggested value
4
0x20
Don’t care value
0x20 suggested value
5
0x01
Don’t care value
0x01 suggested value