background image

The BlueBox™ DA-3G-1x6 Reclocking Distribution Amplifier (hereinafter “BlueBox™ 
DA-3G-1x6”) provides a small “throwdown” package that offers a 1X6 DA with automatic 
detect and reclock at 2.970, 1.485, 1.483, 0.540, 0.360, 0.270, 0.177, and 0.143 Gb/s. The 
outputs can be set to mute if no recognized input is detected. The DA-3G-1x6 can be powered 
from 5-18 VDC using an AC adapter (supplied).

The DA-3G-1x6 can be operated in automatic standard detect mode or in a manual standard 
mode. Reclocking can be bypassed if desired. Non-inverting ASI reclock is available on 3 of 
the 6 output ports.

LED Indicator

The front panel LED indicates video lock. When a 3G or HD rate signal is locked it will light 
green, when an SD rate signal is locked it will light orange. If no signal is locked it will flash 
continuously.

1

Connecting BlueBox™ DA-3G-1x6

1

Connect BlueBox™ DA-3G-1x6 DC power using the supplied AC adapter.

2.

Connect SDI or ASI input. Note the specific output ports that can be used for SDI and/or 

ASI (as shown on the previous page). This provides the basic connections. Other 
connections do not require termination if unused.

Switch Settings

The 4-position switch allows bypassing of the BlueBox™ DA-3G-1x6 reclocker, or forces a 
reclocking rate as shown below.

Specifications

2

3G/HD/S/ASI Reclocking 
Distribution Amplifier

With Bit-Rate Status

SDI/ASI IN

SDI/ASI OUT

SDI OUT

DC IN

SDI OUT

SDI/ASI OUT

SDI/ASI OUT

SDI OUT

Item

Description/Specification

SDI Input:

SMPTE 424M, 292, 259M

Input Return Loss:

> 10 dB at 3 GHz
> 12 dB at 1.5 GHz

Environmental:

40-100

°

F (4-38

°

C); non-condensing humidity

Power Input:

+5 - 18 VDC, < 2 W

Dimensions (WxHxD):

6" x 3" x 1" (including connector projections) (152 x 77 x 26 mm)

S1  Bypasses the reclocker. ON for Bypass. OFF for reclocking.

S2S3  Forces a reclocking rate. See above for settings.

S4 Mute control. ON to mute output when input absent. OFF to

unmute output when input is absent.