background image

Installation & Operation Manual

Pizza Perp Tables  

(R290)

Please read this manual completely  before installing or operating this unit!

Blueair FSE reserves the right to make product modification at any time. 

Specifications and Designs are subject to change without notice.

IMPORTANT SAFETY INSTRUCTION (SAVE THESE INSTRUCTIONS)

Visit our website at 

www.blueairfse.com

BAPP44-HC

BAPP67-HC

BAPP93-HC

Содержание BAPP44-HC

Страница 1: ...e installing or operating this unit Blueair FSE reserves the right to make product modification at any time Specifications and Designs are subject to change without notice IMPORTANT SAFETY INSTRUCTION SAVE THESE INSTRUCTIONS Visit our website at www blueairfse com BAPP44 HC BAPP67 HC BAPP93 HC ...

Страница 2: ...onwide Sevice Network Toll Free 1 866 677 8500 TEL 310 808 0102 FAX 310 808 0242 Visit our website at www blueairfse com Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 Installation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 Maintenance Cleaning _ _ _ _ _ _ _ _ _ _ 4 Operation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5 Troubleshooting _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 Installing Casters _ _ _ _ _ _ _ _ _ _...

Страница 3: ...xplosion due to flammable refrigerant used Follow handling instructions carefully in compliance with U S and Canadian government Product Pizza PREP Tables Model BAPP44 HC BAPP67 HC BAPP93 HC Capacity cu ft 11 3 20 2 30 8 Exterior Dimensions includes 5 casters Width 44 3 8 67 93 1 4 Depth 36 1 2 Height 42 NET Weight lbs 287 368 452 Electrical Characteristics 115V 60Hz 1Ph Type of refrigeration syst...

Страница 4: ...ain proper sealing 1 INDOOR USE ONLY 1 This unit is intended for indoor use only 2 FOR LOCATION 1 Be sure that the location is strong enough to support the total weights of unit and the content 2 Keep the unit away from sunlight and other heat generating equipment 3 The minimum clearance between the back of the unit and wall should be 7 inches at least 3 INSTALLING CASTERS 1 Be sure that casters w...

Страница 5: ...et interior 2 The controller has been preset NORMAL position at the factory 3 Set the control knob toward COOL for higher temperature and COLD for lower temperature 4 The thermostat controls compressor s ON OFF by sensing inside temperatures of cabinet 5 The unit is equipped with an off cycle defrost ...

Страница 6: ...turn it clockwise to set a desired temperature Performance Issue Move the unit from direct sunlight Move the unit away from heat generating devices Install the unit in a well ventilated area with at least 7 Inches of clearance on all sides Clean the condenser if heavy dust is collected Clear contents from blocking the air duct in the interior Check the temperature controller for incorrect setting ...

Страница 7: ...7 1 Remove the outer packing 2 Install the casters in the area 3 Maker sure that castors with brakes should be installed in front ...

Страница 8: ...8 ...

Страница 9: ...______________________ Extended Warranty Option Additional 1 Year Parts Labor extended Warranty available Please make check payable to TITAN and Return with this registration card 口 Yes I would like the extended warranty 口 No I would not like the extended warranty Signature of Business Owner ______________________________ Date _____________________ Zip ________ __ Customer Name ___________________...

Страница 10: ...Blueair FSE LLC 223 W Rosecrans Ave Gardena CA 90248 Toll Free 1 866 677 8500 TEL 310 808 0102 FAX 310 808 0242 Visit our website at www blueairfse com ...

Отзывы: