NA3424 – In-line Automatic 9-lb Chlorine Feeder
for Above Ground Pools
INSTALLATION AND OPERATING INSTRUCTION
YOUR AUTOMATIC CHLORINE FEEDER
is designed for installation in the return line (PCF03) to your pool or next to (PCF04)
your filter
system. When next to your filter system, it operates by the pressure differential of the system, which draws water through
the feeder. It uses slow dissolve Trichloro-S-Triazinetrione (Tri-Chlor) large or small tablets (or sticks) ONLY. No other type of chemicals
should ever be used in your chlorine feeder. Your automatic chlorine feeder holds up to 18 large (3") tablets (about 9-lbs) and has a dial
type control valve to regulate the rate of water flow through the chlorine feeder. This large capacity feature, under normal conditions,
should provide a minimum of two weeks chlorination for large pools. By regulating the valve setting between
FULL
(more chlorine) and
OFF
(no chlorine) and the amount of Tri-Chlor tablets you place in the feeder, you can easily adjust the chlorine feed rate that is
necessary to maintain the proper chlorine residual for your pool.
CAUTION - READ CAREFULLY
This chlorine feeder is designed to use Trichloro-S-Triazinetrione tablets - slow dissolving type. NEVER MIX with other types of chlorine or
chemicals. Explosion or fire may result. Exercise extreme caution when opening or servicing your feeder. Always shut off pump and
available valves before opening. Do not inhale fumes from any chemical feeder or container. Protect your eyes, skin and clothing from
chemicals at all times. NEVER open chlorinator when pump is running. To prevent build up gas in chlorine feeder, be sure pool return line
valve(s) is kept open - except when opening/servicing unit. Always read label and carefully follow chlorine manufacturer's and dealer's
recommendations for proper water conditioning and daily chlorine requirements for your particular pool and area.
DIRECTIONS FOR USE
Before start-up of your chlorine feeder, your pool/spa should be properly conditioned and have a chlorine residual of approximately 1.1
to 1.5ppm.Follow dealer and chemical manufacturer's directions and instructions. The chlorine demand for pools and spas varies based
on use, temperature, sunlight etc. Initially, you will have to experiment to determine the proper amount of chlorine and the correct valve
setting required for your pool and filter time cycle. Using a 20,000 gallon pool as a guide, we suggest you place about 8 large, slow
dissolving Tri-Chlor tablets (or about 4-lbs of small slow dissolve tablets or sticks) in your feeder and place the dial valve setting at #3.
(Reduce or increase the amount of chlorine according to pool size, i.e., 30,000 gallon - add 50% more tablets) Check chlorine residual
daily and adjust dial valve for more or less chlorine. Increasing the quantity of chlorine in your feeder will extend the time between
exchanging your feeder with more chlorine.
EASY-LOCK COVER
To open:
1.
Shut off pump and turn DIAL CONTROL VALVE to OFF. Shut off any other in-line valves to prevent back flow; if applicable. Wait one minute.
2.
Turn the LID counter-clockwise to open.
Caution: do not inhale fumes from chlorine feeder.
To close:
1.
Press the LID, with O-ring seal, firmly onto BODY. Engage the LID threads and turn clockwise to stop lug.
2.
Place DIAL CONTROL VALVE to desired setting, open In-line valves and re-start pump.
INSTALLATION OF PCF03 (IN-LINE)
1.
Your automatic chlorine feeder is for permanent installation in the pool water return line.
2.
Always install chlorine feeder after the heater. If there is no heater, install after the filter. Damage to the heater or filter may result if
concentrated chlorine is allowed to flow through them.
3.
Your automatic chlorine feeder is furnished with 1 ½” female threads. Socket adapters may also be used. Use pipe thread sealants
formulated and approved for the use with plastic connections. Do not over tighten.
4.
The preferred installation is above water level and located in line below filter or heater outlets. An in- line positive seal corrosion resistant
check valve should be installed to reduce backflow of chlorine gas when the system is shut off. If the chlorine feeder must be located
below water level, provide check valve to prevent water backflow when opening/servicing the unit.