4
Specifications
Electrical Supply Requirements
Electrical Connection
When connecting this appliance to the mains supply, ensure that the following is carried out:-
An isolating switch is fitted within 2m of the appliance, but not on the appliance and in such a
position that the user does not have to reach across the cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (As per AS / NZS 3191
Part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
The branch supply line shall be individually overload protected to the correct current rating and
the supply chord shall be protected against any mechanical or thermal damage.
A grommet is fitted around the wiring entry hole into the appliance.
All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance for the
current drawn on that line.
MODEL
1-Phase Connection
1P+N+E
230-240V
3-Phase Connection
3P+N+E
400-415V
GPE506
GPE508
6.5 kW,
26.6 Amps @ 235 V
6.5 kW
L1 - 8.2 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
GPE56
GPE58
6.8 kW,
27.9 Amps @ 235 V
6.8 kW
L1 - 9.5 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
Warning
Содержание Evolution GPE506
Страница 7: ...5 Dimensions GPE506 GPE56 GPE508 GPE58 ...
Страница 19: ...17 Wiring Schematics Static Ovens GPE506 and GPE508 ...
Страница 20: ...18 Wiring Schematics Convection Ovens GPE56 and GPE58 ...
Страница 21: ...19 Wiring Schematics Wiring Layout for Static Oven Wiring Layout for Convection Oven ...
Страница 27: ......