3
Specifications
Model Numbers Covered in this Specification
GPE506
Gas Griddle Range, Electric Static Oven
- 900mm.
GPE56
Gas Griddle Range, Electric Convection Oven - 900mm.
GPE508
Gas Griddle Range, Electric Static Oven
- 1200mm.
GPE58
Gas Griddle Range, Electric Convection Oven - 1200mm.
Gas Supply Requirements
(*) NOTE:
Measure the burner operating pressure at the manifold test point with burner operating at
the 'High Flame' setting.
NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
TOWN GAS Only - The burner operating pressure is to be adjusted using the Town Gas
adjustable gas regulator supplied.
Refer to the ‘Gas Conversion and Specifications section of this manual for further details.
Natural Gas
LP Gas / Butane
Town Gas
GPE506/
GPE56
GPE508/
GPE58
GPE506/
GPE56
GPE508/
GPE58
GPE506/
GPE56
GPE508/
GPE58
Input Rating
(N.H.G.C.)
80 MJ/hr
(75,825 BTU)
108 MJ/hr
(102,364 BTU)
80 MJ/hr
(75,825 BTU)
108 MJ/hr
(102,364 BTU)
80 MJ/hr
(75,825 BTU)
108 MJ/hr
(102,364 BTU)
Supply Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18” w.c.)
0.75 - 1.50 kPa
(3” - 6” w.c.)
Burner Operating
Pressure
0.90 kPa
(3.6”w.c.)
2.6 kPa
(10.2” w.c.)
0.63 kPa
(3” w.c.)
Gas Connection
¾” BSP Male
Содержание Evolution GPE506
Страница 7: ...5 Dimensions GPE506 GPE56 GPE508 GPE58 ...
Страница 19: ...17 Wiring Schematics Static Ovens GPE506 and GPE508 ...
Страница 20: ...18 Wiring Schematics Convection Ovens GPE56 and GPE58 ...
Страница 21: ...19 Wiring Schematics Wiring Layout for Static Oven Wiring Layout for Convection Oven ...
Страница 27: ......