background image

21 

Gas Conversion and Specifications 

NOTE, Pin rotated 

for Natural Gas 

NOTE, Pin rotated 

for LPG 

Gas Regulator 

 

NOTE: 

Gas regulator supplied is 

 

convertible between Natural Gas 
and LP Gas, but it’s outlet 

 

pressure is fixed ex-factory and 
is NOT to be adjusted. 

 
 
 
 
 
 
 

 
 

- Town Gas Only. 

 

1. 

Remove slotted cap from regulator. 

2. 

Turn ‘On’ gas supply and appliance. 

3. 

Adjust pressure adjusting screw to achieve correct burner 

operating pressure. 

 

NOTE:  Measure burner operating pressure at manifold test 

point with one burner operating at 'High Flame' setting. 

 

4. 

Verify operating pressure remains correct (Re-adjust regulator 

if required). 

5. 

Screw cap nut back onto regulator. 

 
 

Gas Type Labels 

On completion of gas conversion, replace gas type labels located at:- 
 

- Rear of unit, above gas connection. 

 

- Beside rating plate. 

 
 

Commissioning 

Before leaving installation; 
1. 

Check all gas connections for leakage using soapy water or other gas detecting equipment. 

2. 

Carry out a ‘Commissioning’ check of appliance as shown in Installation Section of this manual. 

3. 

Ensure any adjustments done to components that have adjustments / settings paint sealed are to be 

re-sealed. 

 

NOTE:  If for some reason it is not possible to get appliance to operate correctly, shut ‘Off’ gas  

supply and contact supplier of this appliance. 

 

 
 

D

O

 

NOT

 

USE

 

A

 

NAKED

 

FLAME

 

TO

 

CHECK

 

FOR

 

GAS

 

LEAKAGES

Warning 

Pressure Adjusting 

Screw 

Cap Nut 

Содержание Evolution GPE506

Страница 1: ...GAS GRIDDLE RANGES ELECTRIC OVEN GPE506 GPE56 GPE508 GPE58 I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L 232432 8 ...

Страница 2: ...ares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales t...

Страница 3: ...ion Dimensions 5 Installation 6 Installation Requirements Unpacking Location Clearances Assembly Gas Connection Electrical Connection Commissioning Operation 10 Operation Guide Description of Controls Lighting the Griddle Pilots Lighting the Griddle Main Burners Re setting the Overtemp Device All UK and Optional Non UK Models Turning Off the Griddle Main Burner Pilot Oven Cleaning and Maintenance ...

Страница 4: ... OPERATOR MUST TAKE GREAT CARE TO USE THE EQUIPMENT SAFELY TO GUARD AGAINST RISK OF FIRE AND INJURY THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER ...

Страница 5: ... apart from when converting between gasses if required TOWN GAS Only The burner operating pressure is to be adjusted using the Town Gas adjustable gas regulator supplied Refer to the Gas Conversion and Specifications section of this manual for further details Natural Gas LP Gas Butane Town Gas GPE506 GPE56 GPE508 GPE58 GPE506 GPE56 GPE508 GPE58 GPE506 GPE56 GPE508 GPE58 Input Rating N H G C 80 MJ ...

Страница 6: ...y line shall be individually overload protected to the correct current rating and the supply chord shall be protected against any mechanical or thermal damage A grommet is fitted around the wiring entry hole into the appliance All wiring connections must be tight Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance for the current drawn on that lin...

Страница 7: ...5 Dimensions GPE506 GPE56 GPE508 GPE58 ...

Страница 8: ... the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic coating from the exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor Ensure that the 4 adjustable feet are fitted with the protruding centre screw Report any deficiencies to the distributor w...

Страница 9: ...ual b Supply Pressure required for this appliance is shown in the Specifications section of this manual Check the gas supply to ensure adequate supply pressure exists c Input Rate of this appliance is shown on the Rating Plate and in the Specifications section of this manual The input rate should be checked against the available gas supply line capacity Particular note should be taken if the appli...

Страница 10: ...t behind the appliance This switch must be clearly marked and readily accessible in case of fire 1 Check that the electricity supply is correct to as shown on the Rating Plate attached to the lower front hand side of the front sill panel 2 The supply terminal connections are located at the rear of the appliance Refer to Electrical Connections in the Dimensions section of the manual 3 Open the oven...

Страница 11: ...ng instructions specified in the Operation section of this manual Light the Griddle Pilot Burner Light the Griddle Main Burner Check the Griddle Low Fire Operation Check the Oven Heating Check the Oven Thermostat Operation Check the Oven Fan Operation GPE56 and GPE58 Ovens Only Ensure that the operator has been instructed in the areas of correct lighting operation and shutdown procedure for the ap...

Страница 12: ...r Lamp White Heating Indicator Lamps Amber for Top Bottom Elements Oven Top Heat Control ๐ OFF Position LOW Position 1 Position 2 Position 3 Position 4 Position HIGH Position This appliance is for professional use and is only to be used by qualified persons Only authorised service persons are to carry out installation servicing or gas conversion operations Components having adjustments protected e...

Страница 13: ...piezo igniter button on the front control panel 2 Rotate the gas control knob anti clockwise to the desired temperature marked on the knob 3 The main burner will now ignite automatically off the pilot burner Re Setting the Overtemp Device All UK and Optional Non UK Models This griddle is fitted with an overtemp device which isolates the gas supply to the burners should the gas control system or th...

Страница 14: ...ven top heat control is set to a high setting proportionally more heat is produced at the top of the oven This can be used for browning etc during the cooking operation With the oven top heat control set on a low setting less heat is produced from the top oven elements This mode is used for general baking purposes to prevent cakes etc from getting too brown and crisp on the top but allows the cake...

Страница 15: ... to prevent the forming of rust on the griddle plate Steel Plate ensure that any detergent or cleaning material has been completely removed after each cleaning The appliance should be switched on briefly to ensure the griddle plate becomes dry Oil or grease should be spread over the griddle surface in order to form a thin protective greasy film To keep your range clean and operating at peak effici...

Страница 16: ...gents as they will damage the range and burners DO NOT use water on the griddle plates while they are still hot as warping may occur Allow these items to cool before cleaning Griddle Steel Plate NOTE To prevent rust forming on the griddle plate ensure that all detergent and cleaning material has been entirely removed after each cleaning process Turn On the appliance briefly to dry the griddle plat...

Страница 17: ...ts or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cleaner when the appliance is cold and rub in the direction of the grain c Remove the grease drawer and clean with a mild anti bacterial detergent and hot water solution using a soft bristled brush Dry the grease drawer thoroughly with a dry cloth Stainless Steel Surfaces a Clean the exteri...

Страница 18: ...re not empty Call the service provider Pilot goes out when gas control knob released Releasing knob before the thermocouple has heated Pilot flame too small Gas pressure too low Partially blocked pilot injector Thermocouple connection to the gas control is loose or faulty Thermocouple faulty Hold knob in for at least 20 seconds following ignition of the pilot Clean or replace the pilot injector Ti...

Страница 19: ...17 Wiring Schematics Static Ovens GPE506 and GPE508 ...

Страница 20: ...18 Wiring Schematics Convection Ovens GPE56 and GPE58 ...

Страница 21: ...19 Wiring Schematics Wiring Layout for Static Oven Wiring Layout for Convection Oven ...

Страница 22: ...iter Slacken the gas supply tube at gas control end Disconnect gas supply tube to the pilot burner 2 Remove pilot injector and replace with correct size injector as shown in the Gas Specifications Tables at the rear of this section 3 Reconnect the following Gas supply tube to pilot burner Tighten gas supply tube at gas control end Refit piezo igniter Re connect lead to piezo igniter Low Fire Adjus...

Страница 23: ... Re adjust regulator if required 5 Screw cap nut back onto regulator Gas Type Labels On completion of gas conversion replace gas type labels located at Rear of unit above gas connection Beside rating plate Commissioning Before leaving installation 1 Check all gas connections for leakage using soapy water or other gas detecting equipment 2 Carry out a Commissioning check of appliance as shown in In...

Страница 24: ...nversion and Specifications section in this manual for further details Natural Gas LPG Butane Town Gas Main Burner GPE506 GPE56 3 00mm 1 80mm 1 65mm 5 50mm GPE508 GPE58 2 85mm 1 70mm 1 55mm 5 20mm Pilot Injector 0 41 0 75 Low Fire Adjustment 1 Full Turn Counter Clockwise from the Fully In Position High Fire Adjustment Maximum Flow Screw Fully In c w Burner Operating Pressure 0 90 kPa 2 6 kPa 0 63 ...

Страница 25: ...Main Injector Butane 1 55mm GPE508 GPE58 032550 Main Injector Town Gas 5 50mm GPE506 GPE56 032520 Main Injector Town Gas 5 20mm GPE508 GPE58 019593 Pilot Injector Nat Gas 0 41 019594 Pilot Injector LPG Butane 0 25 026393 Pilot Injector Town Gas 0 75 Oven 228082 Oven Top Element 2kW 228059 Oven Bottom Element 4 5kW 227963 Indicator Neon Amber 228922 Indicator Neon White 229146 Thermostat 50 300 C 2...

Страница 26: ...00mm Range Gas Regulators Gas Conversion Kits Australia New Zealand Only UK Only Griddle Plate Standard Chromed C Ribbed Chromed Options 900mm PGH920 ON REQUEST depending on ribbed section width on LH or RH side 1200mm PGH1220 PGH1220C PGH920C Gas Type Gas Regulators Part No Description Nat Gas LPG Butane 228531 BSP F F Convertible Town Gas 230185 BSP F F Adjustable Models Gas Type to Convert to N...

Страница 27: ......

Отзывы: