11
Operation
Lighting the Griddle - Pilots
These griddles are fitted with a pilot as a standard option and Flame Failure Protection, which is
incorporated by way of a thermo-electric system for each main burner. Flame Failure Protection will shut
‘Off’ the gas supply to that burner in the event that the pilot for that burner goes out, so that any un-burnt
gas is not expelled.
This is an important safety feature which is slowly becoming law
throughout the world
.
1.
Depress the gas control knob and rotate anti-clockwise to the ‘PILOT’ position.
2.
With the gas control knob depressed, press the piezo igniter until the pilot burner ignites. (Each
operation of the piezo igniter button will generate a single spark).
3.
Hold ‘IN’ the gas control knob for 10-15 seconds, then release. The pilot burner should remain
alight. (If not, repeat Steps 1 to 3 above). Pilot ignition can be viewed through the opening in the
piezo igniter plastic surround.
4.
To light the remaining pilots, repeat Steps 1 to 3 above.
NOTE: If the pilot burner goes out during normal operation wait 5 minutes before attempting to
re-light the pilot burner.
Lighting the Griddle - Main Burners
1.
Ensure that the pilot burner is alight by checking through the opening in the plastic surround fitted
to the piezo igniter button on the front control panel.
2.
Rotate the gas control knob anti-clockwise to the desired temperature marked on the knob.
3.
The main burner will now ignite automatically off the pilot burner.
Re-Setting the Overtemp Device (All UK and Optional Non-UK Models)
This griddle is fitted
with an overtemp device which isolates the gas supply to the burners should the gas
control system or thermostat malfunction, thus preventing overheating of the griddle. If the pilot fails to
ignite after several attempts, ensure that the overtemp is checked to ensure that it has not tripped.
1.
To reset the overtemp, remove the gas
control knobs from the front of the
griddle.
2.
Slacken the 2 screws securing the front
control panel and carefully remove the
control panel, ensuring that the leads to
the piezo igniter are disconnected from
the rear of the piezo igniters.
3.
Using a small screwdriver, depress the
centre of the overtemp reset button.
4.
Re-connect the piezo igniter leads to
the piezo igniters.
5.
Refit the front control panel and secure
with the 2 securing screws.
6.
Refit the gas control knobs.
7.
Attempt to re-light the pilot burners as shown above. Should the pilot burners still not ignite, call a
qualified service person to investigate the problem.
Overtemp fitted to
Gas Control Valve.
O v e r t e m p
reset button
Fig 5
S
URFACE
TEMPERATURE
OF
THE
GRIDDLE
PLATE
CAN
REACH
OVER
350°C
WHEN
THE
APPLIANCE
IS
OPERATED
AT
FULL
HEAT
SETTING
.
Warning
Содержание Evolution GPE506
Страница 7: ...5 Dimensions GPE506 GPE56 GPE508 GPE58 ...
Страница 19: ...17 Wiring Schematics Static Ovens GPE506 and GPE508 ...
Страница 20: ...18 Wiring Schematics Convection Ovens GPE56 and GPE58 ...
Страница 21: ...19 Wiring Schematics Wiring Layout for Static Oven Wiring Layout for Convection Oven ...
Страница 27: ......