Blue Sea Systems 7521 (25A) Скачать руководство пользователя страница 1

Read and understand the contents of this User Manual. It contains important safety, handling, and operational instructions for the P12 Battery Chargers.
This User Manual describes the product mentioned herein at the time of its publication. Specifications and performance are subject to change at the discretion 
of Blue Sea Systems. To view the most current revision of this publication visit bluesea.com/P12.

Scan for 
additional
product
information

P12

User Manual

7521 

(25A)

 and 

7522 

(40A)

BATTERY CHARGER

12V DC

CHARGING

ALERT

C H A R G I N G   S T A G E

EQUALIZE – ALL LIGHTS FLASH

FLOAT

ABSORB

BULK

PREFLOAT

www.bluesea.com

Patent Pending

P12

QuickGuide

BATTERY CHARGER

N° article  

 7521  7522

Courant maximum de sortie totale  

 25A  40A

Tension de sortie nominale             

   12V CC

Raccordements de sortie 

   3 positifs

 

   1 négatif

Tension d'entrée CA

 universelle   

   90–265V CA

Fréquence d'entrée CA

 nominale  

   45–65 Hz

Tension de sortie maxi.  

   16,0V CC

Précision de tension de sortie      

   0.05V CC

Température de fonctionnement mini.   

-20°C (-4°F) 

Température de fonctionnement maxi.  

 70°C (158°F)

Température de stockage mini.       

  -30°C (-22°F) 

Température de stockage maxi.        

   80°C (176°F) 

Courant parasite maxi.           

   2mA    

    

 Regulatory

Design and construction compliance to UL-1236 

marine (including ignition protection) and CSA

  22.2 

No. 107.2-0 standards. Meets all elements of the 

ABYC A-31 and certain NMEA

 requirements

. To view 

the most current regulatory certifications, 

visit www.bluesea.com/P12.

Part Number 

 7521  7522

Total Output Current (Limited) 

 25A  40A

Nominal Output V

oltage 

 12V DC

Output Connections 

 3 positive

 

 1 negative

 Universal AC Input V

oltage 

 90–265V AC

Nominal AC Input Frequency 

 45–65 Hz

Maximum Output V

oltage 

 16.0V DC

Output Voltage 

Accuracy  

 0.05V DC

Minimum Operating 

Temperature 

-20°C (-4°F)

    

Maximum Operating 

Temperature 

 70°C (158°F)

Minimum Storage 

Temperature 

-30°C (-22°F) 

Maximum Storage 

Temperature 

 80°C (176°F) 

Maximum Parasitic Current 

 2mA    

    

 

DESIGN

ED 

ASSEMB

LED

and TEST

ED

in the 

USA

Содержание 7521 (25A)

Страница 1: ...lle 90 265VCA Fr quenced entr eCAnominale 45 65Hz Tensiondesortiemaxi 16 0VCC Pr cisiondetensiondesortie 0 05VCC Temp raturedefonctionnementmini 20 C 4 F Temp raturedefonctionnementmaxi 70 C 158 F Tem...

Страница 2: ......

Страница 3: ...Default Voltages by Battery Type Product Dimensions and Installation Clearances 6 Included Components 7 Supplies Needed 8 Installation Instructions 9 10 Initial Charger Setup 11 Advanced Charger Setup...

Страница 4: ...icing GROUNDING PRECAUTIONS Marine battery chargers and inverters have two grounding connections one from the AC system and one from the DC system ABYC requires the AC grounding system to be connected...

Страница 5: ...and at the batteries DC reverse polarity protection DC over voltage protection and surge and short circuit protection The definitions of the P12 charging stages are defined below The charging stage LE...

Страница 6: ...tons Charging stage indicators Termination cover latch Charging and Alert indicators Graphic LCD Display Termination insulating cover DC output DC strain relief clamp AC strain relief and insulating c...

Страница 7: ...roup 31 Conductor Length in feet meters Charger Rating 25A 40A 6 ft 1 83 meters 14 AWG 2 5mm 8 AWG 10mm 10 ft 3 05 meters 12 AWG 4mm 8 AWG 10mm 15 ft 4 57 meters 10 AWG 6mm 6 AWG 16mm 20 ft 6 09 meter...

Страница 8: ...66 93mm Product Dimensions 6 WARNING For drip proof performance and to meet ABYC requirements the P12 Battery Charger must be mounted vertically as shown below TOP Recommended side clearance 1 97 50m...

Страница 9: ...ne screws Use 1 Phillips screwdriver Recommended torque 5 10 in lb 0 6 1 1 Nm M6 serrated flange hex nuts Use 10mm socket wrench with extension Recommended torque 70 80 in lb 8 9 Nm M6 serrated flange...

Страница 10: ...rivers Flat blade screwdriver Phillips 1 for AC Termination cover and DC Termination Strain Relief clamp Phillips 2 for AC termination screws Phillips 3 for mounting screws 6 Socket wrench 10mm socket...

Страница 11: ...teries to minimize wire length and its associated voltage drop to maximize charging efficiency If the batteries are not close together place the charger near the largest bank of batteries NOTE DC wiri...

Страница 12: ...t do not energize the circuit until AC covers are installed DC is connected and DC fuses are installed Wiring Connections 1 Attach the battery charger remote connection to the back of the P12 Battery...

Страница 13: ...elect button 4 Once the desired battery type is highlighted press the OK button Press the Cancel button to go back Note If User mode is selected batteries will not charge until Absorb and Float voltag...

Страница 14: ...designated maximum amperage is the total available amperage to be supplied among all 3 outputs Selecting an amperage less than the maximum could result in under charging of batteries 5 Press the OK bu...

Страница 15: ...lected battery type The default Absorb voltages for each battery type can be seen in Table E above Warning Incorrect Absorb and Float voltages could reduce the life of your batteries Contact your batt...

Страница 16: ...ive while in Absorption and still change to Float If a load is active and drawing more than the designated End Absorption Amps the battery bank will not leave Absorption until the maximum Absorption t...

Страница 17: ...erences it is important to regulate output voltage with temperature A battery in a freezing environment should not be charged the same as a battery in a hot environment The P12 Battery Charger is set...

Страница 18: ...eries are fully charged by verifying the charger is in Float mode with no active loads 2 Turn off or disconnect all DC devices that are connected to the batteries Disconnect the battery banks not bein...

Страница 19: ...You may pause Equalization at any time by pressing the pause button 17 If at any point during Equalization a DC load is applied to the battery being equalized Equalization will stop 18 You may stop Eq...

Страница 20: ...o Get Here From the Charger Summary Screen select the Menu button From other screens select the Back button Display Setup The Display Setup allows the user to customize the display settings Options Ad...

Страница 21: ...if time is being added or subtracted from the timer If paused the charger is in Float or Standby and the Absorb Timer will remain at its current time Read about Absorb Timers on page 14 Options Selec...

Страница 22: ...urrents during charging The aluminum case of the P12 Battery Charger provides a large amount of heat dissipation but for optimal performance the fan must be performing properly If at any point the fan...

Страница 23: ...components on the P12 Battery Charger If any of the vital hardware components fail the Hardware Failure Alert Screen will appear Shut off AC power for two minutes and then attempt to restart If there...

Страница 24: ...battery banks However due to the P12 Battery Charger s ability to independently optimize charging for each battery bank it is favorable to isolate all battery banks by disengaging the ACR s ability t...

Страница 25: ...h to the starter solenoid NOTE Connecting the SI Start Isolation wire to only one of the ML ACR isolation wires will not properly integrate the P12 battery charger with your ML ACR 3 Connect a wire fr...

Страница 26: ...s Silence function for alarms Output User adjustable charger output when AC source limitations exist that require lowering the AC current draw Standby Places P12 Battery Charger into standby mode Spec...

Страница 27: ...screwdriver Recommended torque 5 10 in lb 0 6 1 1 Nm 1 Four Mounting Screws 2 One Cover 3 One Remote Assembly 4 One Mounting Gasket 5 One 25 ft 7 6 m Cat5e Cable 6 One Packet of Dielectric Grease 4 15...

Страница 28: ...d to monitor the output on three batteries and limit the output using the output button In normal operation the Charge Output LEDs show the percentage of the absolute maximum current on each battery T...

Страница 29: ...ternal fan is not working properly See page 20 for more details 9 DC Fuse BLINKING Red Indicates the chargers internal DC fuse is blown The P12 Battery Charger has two internal DC fuses that are not a...

Страница 30: ...which the product was purchased by the first retail customer 2 The date on which the first retail customer purchases a vessel on which the product was installed Blue Sea Systems will at its sole discr...

Страница 31: ...oltage and Frequency measurement with alarms 2 AC ELCI Ground Fault Protection 3 AC Source Selection 4 AC Branch Circuit Protection and Switching 5 DC Battery Charger Remote Monitoring and Control 6 D...

Страница 32: ...425 Sequoia Drive Bellingham WA 98226 USA p 360 738 8230 p 800 222 7617 USA and Canada Customer Service f 360 734 4195 conductor bluesea com www bluesea com 980012000 Rev 005...

Отзывы: