Blue Ribbon BB4000 Скачать руководство пользователя страница 1

Blue Ribbon Corporation

Instruction Manual

Model BB4000

Station Controller

Blue Ribbon Corp

2770 Long Road

Grand Island, NY 14072

Ph:  716-773-9300

email:  [email protected]

Website:  www.blueribboncorp.com

DISCLAIMER: No representations or warranties are made with respect to the contents of this Instruction Manual. Blue Ribbon Corp 

reserves the right to revise this manual and to make changes periodically to the content thereof, without obligation 
to notify any persons of such revisions.

Содержание BB4000

Страница 1: ...email brsales blueribboncorp com Website www blueribboncorp com DISCLAIMER No representations or warranties are made with respect to the contents of this Instruction Manual Blue Ribbon Corp reserves t...

Страница 2: ...nge a Setup Parameter Value 3 2 3 How to Simulate Levels 4 2 4 How to Enter the Security Code 4 3 Menu System Setup 5 4 Menu Data Display 10 5 Pump Call Sequence setup parameters 12 5 1 Number of Pump...

Страница 3: ...s 18 8 1 Pump 1 2 3 4 Disable Functions 1 4 18 8 2 Level Freeze Function 5 18 8 3 External Alternation Function 6 18 8 4 On Generator Function 7 19 8 5 All Pump Disable Function 8 19 8 6 Sequence Inpu...

Страница 4: ...6 Last Fault Code Parameter LFC 24 9 7 Fault Code Table 25 10 Analog Level Input 4 20 mA Input Calibration Procedure 27 10 1 Level Input Zero Parameter P 25 27 10 2 Level Input Span Parameter P 24 27...

Страница 5: ...3 13 5 Flow Calculator Surface Area Calculation 34 13 6 Flow Calculator Display Parameters 34 14 Communication With a SCADA System 35 14 1 MODBUS Functions Supported 35 14 2 Setup for Connection to a...

Страница 6: ...ctivity Indicator 46 19 2 Address of Last Slave Polled by Master 47 19 3 Record of Last Modbus Message 47 19 4 Communication Fault Codes 47 20 Connection Diagram 48 20 1 Standard Features 48 20 2 Conn...

Страница 7: ...ump fault External Lead Pump Selector Switch All pump disable for connection to Phase Monitor Return to Table of Contents Limit number of pumps called while on emergency power Alternation by External...

Страница 8: ...gulated 20Vdc 1V Transient Protected Analog Outputs Isolated 4 20mA Maximum Load Resistance 600 Auxiliary Analog Inputs Isolated 4 20mA 250 Load Transient Protected 1 5 Ordering Information Part Numbe...

Страница 9: ...henever the indicator next to the Para meter label is on Parameters in the System Setup Sub Menu The value of the Parameter in the System Setup Sub Menu may be viewed by using the push button PB M to...

Страница 10: ...PB S Note The Simulation starts from the actual level displayed prior to entering the Level Simulation mode 2 Press push button PB D or PB U as needed to change the simulated level 3 To end the level...

Страница 11: ...ecurity Code may be Customized using Parameter P 26 See Page 6 P 13 4 Number of Pumps Present See Page 12 1 1 Pump 2 2 Pumps 3 3 Pumps 4 4 Pumps P 14 4 Number of Pumps Allowed to Run at the Same Time...

Страница 12: ...5 1 sec Stop Pump Delay Range 1 100 seconds Note This is the Time Period that the Wet Well Level Must Remain At or Below At or Above for Pump UP P 19 2 the Respective OFF Level Setting in order to Tur...

Страница 13: ...Telemetry Contact 23 Telemetry J Telemetry Contact 24 Telemetry K Telemetry Contact 25 Telemetry L Telemetry Contact 26 Telemetry M Telemetry Contact 27 Telemetry A Telemetry Contact 28 Telemetry B T...

Страница 14: ...3 Speed Active When Pump 3 is Called 4 Pump 4 Speed Active When Pump 4 is Called 5 Speed Reference any Pump Always Active 6 Copy of Wet Well Level F 24 2 Analog Output 2 Function F 25 3 Analog Output...

Страница 15: ...desired such as Pump Control 4TH On Level set the respective parameter equal to zero 3 An effective Backup Pump Control would involve having a 3 point Level Probe placed high in the wet well The Level...

Страница 16: ...atus Value L 10 Electrode 10 Status Value L 11 Level Probe Test Signal Status Normal Range 230 254 Note This is a Measure of the 8v 60 Hz Square Wave Sent Out to Each Electrode to read the level If th...

Страница 17: ...e 0 255 Where 0 0 0 mA 51 4 0 mA 255 20 mA Note Auxiliary Analog Input data may be read by SCADA in either an 8 Bit or 10 Bit format See Page 30 n 20 Auxiliary Analog Input 2 Status n 21 Auxiliary Ana...

Страница 18: ...uate electrical power running all available pumps at the same time may be a problem This Parameter is used to set an upper limit on the number of pumps called to run at the same time If there is no ne...

Страница 19: ...s a corresponding Pump Off Level setting for each of the Pump On Level settings For the Pump Stop Mode feature to operate the Pump Off Level settings must be set on different levels If all the Pump Of...

Страница 20: ...tting Parameter P 39 on 1 will cause a fixed pump call sequence of 1 2 3 4 Parameter P 39 may also be changed by writing a 0 1 2 3 or 4 to SCADA Register 40022 Parameter Default Value Setting Definiti...

Страница 21: ...Same as Parameter P 39 9 Parameter P 51 may be used to select and setup Time Based Alterna tion 7 2 Pump 1 Always Lead Stays On With Other Pumps Parameter P 16 2 NOTES 1 This sequence is used when it...

Страница 22: ...Alternation would normally be disabled by setting Parameter P 18 to Disabled 9 If connected to a SCADA system alternation may be initiated by momen tarily setting Coil 136 or by forcing the lag pump...

Страница 23: ...nificant difference in the size of the pumps and when only one pump is to be allowed to run at a time When there is a need for more pumping the smaller pump is turned off and the next larger pump is c...

Страница 24: ...eded The one exception to this is the Alternation Sequence Pump 1 Always Lead Parameter P 16 3 where disabling pump 1 will not result in another pump taking its place 8 2 Level Freeze Function 5 When...

Страница 25: ...must expire between each one called to run 8 6 Sequence Input 1 2 3 4 Functions 9 12 When a Discrete Input programmed as a Sequence Input 1 2 3 4 is closed it disables normal alternation and forces on...

Страница 26: ...ator will come on and Fault Code 15 will be generated However this Function does allow pump operation from Float Backup using Functions 32 38 or Level Probe Backup using Parameters b 01 b 07 This Func...

Страница 27: ...Up mode See Page 55 8 14 Float Backup 1st On Level Function 34 When a discrete Input programmed for Float Backup 1st On Level closes the Float Backup logic will issue one pump call assuming that the F...

Страница 28: ...oes not matter how long the input remains closed but it must be opened to reset the logic Typically this input is connected to con tacts from an external Time Clock See Page 31 9 System Status 9 1 Hig...

Страница 29: ...ess it is disabled using Parameter P 50 Low Level Alarm operation may be disabled by setting Parameter P 50 0 This disables Low Level Alarm operation from either the Analog Level Input Parameter F 19...

Страница 30: ...Fault Code Parameter LFC is a copy of the last non zero Fault Code that was present in Parameter FLC Parameter LFC is reset when power is cycled or may be reset by pressing the down push button while...

Страница 31: ...Minimum Speed is set too close to Level at 100 speed They must be at least 0 5 feet apart with P 36 1 or 5 feet with P 36 0 or 0 05 feet with P 36 2 12 VFD Speed Reference Setup Fault Level at Minimu...

Страница 32: ...before Electrode 5 25 Electrode 5 Covered before Electrode 6 26 Electrode 6 Covered before Electrode 7 27 Electrode 7 Covered before Electrode 8 28 Electrode 8 Covered before Electrode 9 29 Electrode...

Страница 33: ...ed up using Parameter P 49 10 1 Level Input Zero Parameter P 25 This parameter is used to make the display read zero feet of water with a Wet Well Level input of 4 0mA Calibration Procedure 1 Apply a...

Страница 34: ...under 5 Repeat the procedure above for the LEVEL INPUT ZERO Parameter 10 3 Level Display Span VS Transducer Calibration Transducer Calibration 4 33 PSI 20mA 5 0 PSI 20mA 10 PSI 20mA 15 PSI 20mA 30 PSI...

Страница 35: ...Default Value Current Value Setting Definitions P 20 50 Minimum speed Percent of Full Speed Range 0 95 P 21 3 5 feet Level at Minimum Speed Range 0 1 99 9 feet P 22 6 0 feet Level at 100 Speed Range 0...

Страница 36: ...an addition al pump is called The pump speed stays at 100 for the time set on the Parameter P 23 then the pump speed returns to normal This feature may be used in cases where a pump is started at a s...

Страница 37: ...Run at the Same Time B Closed Discrete Inputs that are Programmed for Pump 1 2 3 4 Disable or All Pump Disable 5 All backup systems must be setup so that they do not activate within the Flush Cycle o...

Страница 38: ...7 days are all kept stored These flow totals are added together and divided by 7 This value is displayed as either Gallons Per Day or Thousand Gallons Per Day See Parameter P 45 The Average Daily Inf...

Страница 39: ...t faster than 1 foot in 15 seconds with Parameter F 19 1 or faster than one Level Probe Electrode spacing in 15 seconds with Parameter F 19 2 or 3 the logic aborts the measurement and keeps the previo...

Страница 40: ...5 2 Average Daily Inflow Total FdH FdL FdH FdL SCADA Register 40081 Thousand Gallons Gallons Per Day Million Gallons Thousand Gallons Per Day Note If Fault Code 36 Appears Average Daily Inflow Total i...

Страница 41: ...Value Setting Definitions P 28 1 Slave Address See note 1 below Range 0 247 P 33 1 Register Access Mode 1 Read Write See note 2 below 2 Read Only 14 2 Setup for Connection to a SCADA System Notes 1 E...

Страница 42: ...Bits Parameter values of the two devices must be set to match The Delay Before Response Parameter P 32 is provided for cases where the modem needs additional time to prepare itself before receiving a...

Страница 43: ...11 IP Address Range 0 255 Identifier for the device on an IP network E 44 E 41 255 255 255 0 E 44 E 43 E 42 E 41 Subnet Mask Range 0 255 Range of IP addresses that can be Directly connected in the net...

Страница 44: ...4 Remote Control Force Pump On ETM 1 Reset ETM 2 Reset ETM 3 Reset ETM 4 Reset Hi Relay Remote Control With Parameter F 31 2 LO Relay Remote Control With Parameter F 32 2 P1 Relay Remote Control With...

Страница 45: ...mp On Level Float Discrete Input Function 36 3rd Pump On Level Float Discrete Input Function 36 2nd Pump On Level Float Discrete Input Function 35 1st Pump On Level Float Discrete Input Function 34 Lo...

Страница 46: ...Reference Percent of Full Speed 0 100 Same as Parameter d 04 40040 Pump 3 VFD Speed Reference Percent of Full Speed 0 100 Same as Parameter d 05 Register Address Write Read Discrete Input 17 Discrete...

Страница 47: ...1023 40073 Auxiliary Analog Input 3 10 Bit 0 1023 40074 Auxiliary Analog Input 4 10 Bit 0 1023 40080 Flow Calculator Latest Inflow Rate Gallons Per Minute Same as Param FLH FLL 40081 Flow Calculator A...

Страница 48: ...1 If SCADA communication is lost Register 40025 will no longer receive current level data With the loss of communication the Controller will turn off all pumps and turn on the Fault indicator and plac...

Страница 49: ...ster 40010 To return a pump to normal operation clear the respective Coil Upon a loss of serial communication the Pump Disable Logic will be automatically reset and any pump that had been remotely dis...

Страница 50: ...ill be made lead A lead pump selector switch connected to discrete inputs programmed as sequence inputs will also override what is written to Register 40022 The setting may also be changed at Paramete...

Страница 51: ...Alarm is generated when liquid covers the High Level Electrode of a Level Probe Input Parameter b 07 must be setup with the number of the Level Probe Input used to read the High Level The status of th...

Страница 52: ...run times should be made and the registers should reset to zero The ETM data is stored in non volatile memory just prior to a total loss of internal 5V power so the data is not lost during a power out...

Страница 53: ...ntire Modbus message will be present in data Parameters d 08 d 86 If the Slave Address is not acceptable or if any of these errors are encountered the rest of the message is rejected and does not show...

Страница 54: ...48 Model BB4000 Controller Instruction Manual Return to Table of Contents 20 Connection Diagram 20 1 Standard Features...

Страница 55: ...49 Model BB4000 Controller Instruction Manual Return to Table of Contents 20 2 Connection Diagram Optional Analog I O...

Страница 56: ...50 Model BB4000 Controller Instruction Manual Return to Table of Contents 20 3 Connection Diagram Lead Pump Selector Switch...

Страница 57: ...51 Model BB4000 Controller Instruction Manual Return to Table of Contents 20 4 Connection Diagram Analog Level Input 4 20mA Input...

Страница 58: ...52 Model BB4000 Controller Instruction Manual Return to Table of Contents 20 5 Connection Diagram Level Probe...

Страница 59: ...53 Model BB4000 Controller Instruction Manual Return to Table of Contents 20 6 Level Probe Placement and Setup...

Страница 60: ...54 Model BB4000 Controller Instruction Manual Return to Table of Contents 20 7 Control Schematic Example Duplex with 24V Float Backup...

Страница 61: ...55 Model BB4000 Controller Instruction Manual Return to Table of Contents 20 8 Float Backup Example Pump Down...

Страница 62: ...bove the float The Low Level float must close as the level drops below the float 2 Pump Up Applications Parameter P 19 2 Two Float Backup A simple two float backup system can be made using an Off floa...

Страница 63: ...57 Model BB4000 Controller Instruction Manual Return to Table of Contents 20 9 Operator Interface...

Страница 64: ...58 Model BB4000 Controller Instruction Manual 20 10 Enclosure Mechanical Layout Return to Table of Contents Left Side Rear View Right Side Top View...

Страница 65: ...59 Model BB4000 Controller Instruction Manual 20 11 Panel Cutout Return to Table of Contents Not Printed to Scale Do Not Use as a Template...

Страница 66: ...which developed under normal installation use and service and 5 Blue Ribbon Corp is notified in advance of and approves the return by issuing a Return Material Authorization Number and the products ar...

Страница 67: ...on Manual Blue Ribbon Corporation 2770 Long Road Grand Island NY 14072 U S A Tel 716 773 9300 Toll Free 877 774 4751 Fax 716 773 5019 email sales blueribboncorp com Visit our website www blueribboncor...

Отзывы: