About This Guide
ProxySG 900 Series Maintenance & Upgrade Guide
23
Upgrading from the SG900-30 to a SG900-45
Follow the listed steps to upgrade the SG900-30 to a SG900-45.
Upgrade
Steps
Description
1
Power down the appliance. See the
ProxySG 900 Series Quick Start Guide
for additional information.
2
Add additional HDDs.
See, “Hard Disk Drive” on page 35.
3
Replace existing memory modules.
See, “Memory Module” on page 47.
4
Replace the existing CPU and heatsink unit.
See, “Processor (CPU)” on page 57.
5
Power on the appliance. See the
ProxySG 900 Series Quick Start Guide
for additional information.
6
Install new license keys.
See ‘Chapter 3: Licensing’ of the SGOS Admininstration Guide for additional instructions.
Содержание ProxySG SG900-10
Страница 6: ...6 ProxySG 900 Series Maintenance Upgrade Guide...
Страница 28: ...About This Guide 28 ProxySG 900 Series Maintenance Upgrade Guide...
Страница 34: ...34 ProxySG 900 Series Maintenance Upgrade Guide Fan Assembly...
Страница 56: ...56 ProxySG 900 Series Maintenance Upgrade Guide Memory Module...
Страница 86: ...86 ProxySG 900 Series Maintenance Upgrade Guide BIOS Battery...
Страница 103: ......
Страница 104: ...www bluecoat com...