REFRIGERANT SAFETY DATA - R22
7.1
Handling:
Keep away from heat, sources of ignition. Do not puncture or
drop container. Provide sufficient air exchange and / or exhaust in
plant rooms.
7. HANDLING AND
STORAGE:
7.2
Storage:
Keep containers tightly closed in a cool, well-ventilated place.
Store in a cool and shaded area. Do not expose to temperatures
above 50 °C. Keep tightly closed.
8.1
Engineering measures
to reduce exposure:
Ensure adequate ventilation, especially in confined areas.
Personal protection
equipment:
Respiratory protection: In case of insufficient ventilation wear suitable respiratory
equipment, preferably a compressed airline breathing apparatus.
Hand protection:
Impervious butyl rubber gloves.
Eye protection:
Wear as appropriate: safety glasses, goggles, Wear a face-shield
and protective suit for abnormal processing problems.
8.2
Skin and body
protection:
Chemical resistant apron, long sleeved clothing, safety shoes.
8. EXPOSURE
CONTROLS /
PERSONAL
PROTECTION:
8.3
Exposure limit(s):
Chlorodifluoromethane: 3600 mg/m3, 1000 ppm (TLV)
9.1
Stability:
Stable
9.2
Conditions to avoid:
Keep well clear of naked flame and sparks. Do not smoke. If
burned, the product can give off toxic fumes . use self-contained
breathing apparatus.
9.3
Materials to avoid:
alkaline earth metals, alkaline metals, aluminium precipitate, zinc.
9. STABILITY AND
REACTIVITY:
9.4
Hazardous
decomposition
products:
halogenated compounds (e. g. acids), carbonyl halides.
10.1 Acute toxicity:
LC50/inh./4 h/rat : > 300,000 ppm
10.2 Irritation:
10.3 Sensitisation:
Hearth sensitisation: 50,000 ppm
10. TOXICOLOGICAL
INFORMATION:
10.4 Chronic toxicity:
Sub-chronic exposure, effects not observed below level (NOEL):
10,000 ppm
11.1 Waste from residues /
unused products:
Offer surplus and non-recyclable solutions to an established
disposal company. In accordance with local and national
regulations. S59 - Refer to manufacturer/supplier for information
on recovery/recycling.
11. DISPOSAL
CONSIDERATIONS:
Contaminated
packaging:
Do not reuse empty containers. Empty pressure vessels should be
returned to supplier.
No. O.N.U.
1018
12. TRANSPORT
INFORMATIQN:
ADR/RID
UN 1018 Chlorodifluoromethane, 2, 2° A, ADR/RID
Label: 2
Содержание SIGMA 2002
Страница 2: ......
Страница 99: ...Blue Box 93 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 SIGMA 2002 DC MODELS 3 2 13 2...
Страница 100: ...Blue Box 94 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 SIGMA 2002 DC MODELS 14 4 26 4...
Страница 101: ...Blue Box 95 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 HP MODELS 3 2 8 2 14 4 16 4...
Страница 102: ...Blue Box 96 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 HP MODELS 9 2 13 2 18 4 26 4...
Страница 103: ...Blue Box 97 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 LE SIGMA 2002 LE DC MODELS 3 2 26 4...
Страница 104: ...Blue Box 98 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 LE HP MODELS 3 2 26 4...
Страница 105: ...Blue Box 99 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 LC MODELS 3 2 13 2...
Страница 106: ...Blue Box 100 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 LC MODELS 14 4 26 4...
Страница 107: ...Blue Box 101 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 LC HP MODELS 3 2 13 2...
Страница 108: ...Blue Box 102 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 LC HP MODELS 14 4 26 4...
Страница 109: ...Blue Box 103 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 LC DC MODELS 3 2 13 2...
Страница 110: ...Blue Box 104 REFRIGERANT CIRCUIT DIAGRAM SIGMA 2002 LC DC MODELS 14 4 26 4...
Страница 123: ......