SPECIFICATIONS
POWER SUPPLY REQUIREMENTS
120 V, 60 Hz (T50SW, F50SW)
230 V, 60 Hz (200SW, 100SW, 75SW)
MOTOR
Single Phase, Dielectric Oil Filled (T50SW, F50SW)
Permanent Split Capacitor (200SW, 100SW, 75SW)
HORSEPOWER
2 HP...............(
200SW)
1 HP...............
(100SW)
3/4 HP..........
(75SW)
1/2 HP..........
(T50SW, F50SW)
CIRCUIT REQUIREMENT
15 A (minimum)
DIMENSIONS
16-5/8 in. high x 9-5/8 in. base
(T50SW)
17 in. high x 10-5/8 in. base
(F50SW)
18 in. high x 11 in. base
(200SW, 100SW, 75SW)
ON LEVEL (FACTORY SET)
Approximately 19. in.
(T50SW)
Approximately 13 in.
(F50SW)
OFF LEVEL (FACTORY SET)
Approximately 10-1/2 in.
(T50SW)
Approximately 8 in.
(F50SW)
610001W-026 E 1/20
© 2018, Blue Angel/Scott Fetzer Company
CONSTRUCTION
MOTOR HOUSING
Cast Iron
(ALL MODELS)
VOLUTE
Cast Iron (
ALL MODELS
)
IMPELLER
Glass Reinforced Thermoplastic (T50SW,
F50SW)
Cast Iron (200SW, 100SW, 75SW)
SHAFT
Steel
DISCHARGE
2 in. NPT (T50SW, F50SW)
3 in. NPT supplied 2 in. Adapter (200SW,
100SW, 75SW)
Sewage Pump
www.blueangelpumps.com
Intended for Indoor Use Only
T50SW (Tether Float Switch)
F50SW (Vertical Float Switch)
200SW, 100SW, 75SW
Operating Instructions and Parts Manual Sewage
Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
PERFORMANCE GAL/HR
Model
HP
Discharge Head (Lift
Distance)
5 ft 10 ft 15 ft
T50SW
1/2
7680
6600
1920
F50SW
1/2
7680
6600
1920
PERFORMANCE GAL/HR
Model
HP
Discharge Head (Lift Distance)
20 ft 25 ft 30 ft 35 ft 40 ft
200SW
2
-
9600
6400
4000
2300
100SW
1
9800
6300
3400
1300
-
75SW
3/4
6700
3400
1400
-
-